- Autres entreprises Fluke:
- Fluke
- Fluke Biomedical
- Fluke Networks
- Fluke Process Instruments
A Study on the Stability of Standard Platinum Resistance Thermometer in the Temperature Range from 0°C through 720°C
Stabilities of standard platinum resistance thermometers (SPRTs) were tested in the temperature range from 250°C to 720°C. The reason the SPRT stability should be tested not only at the maximum temperature but also at a few other temperatures is explained. Five specially made SPRTs with different filling gases were tested for this purpose. These SPRTs were annealed at four different temperatures (720°C, 675°C, 450°C, and 250°C) for up to 2000 hours. Two SPRTs with higher partial oxygen pressure showed excellent stabilities in the temperature range from 675°C to 720°C, and the total changes in their Rtp during annealing at 675°C for 200 hours were equivalent to less than 0.8 mK. But they were unstable at 250°C and 450°C with drift rates as high as 43 mK per 100 hours at 450°C. SPRTs with lower partial oxygen pressure showed very good stability in the temperature range from 250°C to 450°C, but the one with the lowest partial oxygen pressure showed upward drift in its Rtp in the temperature range from 675°C to 720°C. The factors which caused SPRT drifts were investigated and are discussed.
- Accueil
- Produits
- Nouveautés
- Étalonnage électrique
- Étalonnage RF
- Équipements de test et d'acquisition de données
- Étalonnage de la température
- Étalonnage d'humidité
- Étalonnage de pression
- Manomètres à piston
- Contrôleurs/Étalonneurs
- Moniteurs de pression
- Balances manométriques
- Étalonneurs et moniteurs manuels
- Handheld Pressure Calibrators
- Étalonnage de données d'air
- Moniteurs environnementaux
- Accessoires d'étalonnage de pression
- Systèmes d'étalonnage de pression personnalisés
- Logiciel d'étalonnage de pression
- Étalonnage de débit
- Outils d'étalonnage de process
- Logiciel d'étalonnage
- Service et assistance
- Tous les instruments d'étalonnage
- Instruments de mesure portables
- Où acheter
- Actualités
- Formation
- Littérature et de l'éducation
- Service et Support
- Service Request (RMA)
- Programmes d'assistance
- Assistance technique
- Base de connaissances
- Accréditations
- Centres de service agréés
- Calibration Certificates
- Community Forum
- My MET/SUPPORT
- Manuels des produits (manuels d'utilisation)
- Fiches de données de sécurité (FDS)
- Programme de recyclage
- Safety, Service, and Product Notices
- Garantie
- Téléchargements de logiciels
- Qui nous sommes