Best performance available in an ac/dc resistor
- Long-term stability better than 2 ppm/year (< 1 ppm typical)
- Traceable AC and DC calibrations available
- National lab design proven for more than 25 years
National laboratories around the world have long relied on the standard AC/DC resistors manufactured by Tinsley. Whether they’re used in thermometry or electrical applications—with AC or DC bridges—these resistors perform better than any other AC/DC resistors available.
Six resistors in Fluke Calibration's Model 5430 series cover resistance values from 1 ohm to 10,000 ohms. Each one has an actual resistance within 10 ppm of its nominal value and holds its resistance within 2 ppm per year.
Each resistor comes with a Tinsley certificate on AC performance, traceable to NPL, including calibration uncertainty of 3 ppm. Additionally, Fluke Calibration can provide an optional DC certificate, traceable to NIST and NVLAP accredited, with uncertainty below 1 ppm.
Designed originally by a national lab, Tinsley resistors are bifilar wound to minimize reactance and are filled with oil to minimize both time- and temperature-caused instabilities. AC/DC transfer error at 90 Hz is only 0.1 ppm.
For maintaining your oil resistors, Fluke Calibration provides baths that range from 25- to 155-liter capacity with enough inside shelf space to maintain all your standard resistors. Each of these baths maintains your resistors within 1 mK in the short term (30–60 minutes) and within 5 mK for months at a time.
In our lab, we use both AC and DC bridges in addition to Super-Thermometers. We calibrate SPRTs in fixed points, and we calibrate reference resistors. We use standard resistors every day, and we understand the value of being able to rely on resistors that won’t drift. Tinsley makes the best AC/DC resistors around, and Fluke Calibration makes the best maintenance baths. Ask people who know. Then don’t compromise.
Specifications |
|
| Tolerance | 10 ppm |
| Calibration Uncertainty | AC: 3 ppm (10 kΩ: 4 ppm) DC: 1 ppm (optional) |
| Long-Term Stability | 2 ppm per year |
| Temperature Coefficient | 2 ppm per °C |
| Recommended Current |
1Ω: 100 mA 10Ω: 32 mA 25Ω: 20 mA 100Ω: 10 mA 1 kΩ: 3 mA 10 kΩ: 1 mA |
| Maximum Current |
1Ω: 1 A 10Ω: 320 mA 25Ω: 200 mA 100Ω: 100 mA 1 kΩ: 32 mA 10 kΩ: 10 ma |
| AC/DC Transfer Error (at 90 hz) | 0.1 ppm, typical |
| Model Name | Description |
|---|---|
| 5430-1 Resistor |
AC/DC Standard 1 ohm |
| 5430-10 Resistor |
AC/DC Standard 10 ohm |
| 5430-25 Resistor |
AC/DC Standard 25 ohm |
| 5430-100 Resistor |
AC/DC Standard 100 ohm |
| 5430-200 Resistor |
AC/DC Standard 200 ohm |
| 5430-400 Resistor |
AC/DC Standard 400 ohm |
| 5430-1K Resistor |
AC/DC Standard 1 Kohm |
| 5430-10K Resistor |
AC/DC Standard 10 Kohm |
| 1960 Cal |
DC Standard Resistor |
- Home
-
Products
- New Products
- Electrical Calibration
- RF Calibration
- Data Acquisition and Test Equipment
- Temperature Calibration
- Humidity Calibration
- Pressure Calibration
- Flow Calibration
- Process Calibration Tools
- Calibration Software
- Handheld Test Tools
- Purchase Info
- News
- Training and Events
- Literature and Education
-
Service and Support
- Service Request (RMA)
- Service Plans
- Technical Support
- Knowledge Base
- Accreditations
- Authorized Service Centers
- Calibration Certificates
- Community Forum
- My MET/SUPPORT
- Product Manuals (User Guides)
- Register Products
- Safety Data Sheets (SDS)
- Recycle Program
- Safety, Service, and Product Notices
- Software Downloads
- Warranties
- About Us
Sidebar Request a Quote
Request a quote
We'd like your feedback.
You can help us improve our website »
Thank you!
If you purchased an item from a Fluke authorized distributor, please contact them directly with questions regarding Certificates of Calibration or other documentation.
Support requests for items purchased from, or serviced directly by Fluke and general Metrology questions can be submitted via our online Support Request form and a Fluke representative will be in contact with you.