- Other Fluke companies:
- Fluke
- Fluke Biomedical
- Fluke Networks
- Fluke Process Instruments
See more Fluke brands

| Manufacturer | Model | DUT Type | Reference List |
Procedure Type (Cal Interval) |
DUT Control | |
|---|---|---|---|---|---|---|
|
Agilent |
34972A |
Data Acquisition |
Fluke 5522A, Any Function Generator |
(1 year) |
VISA |
|
|
Agilent |
34972A |
Data Acquisition |
Fluke 5522A, Any Function Generator |
(N/A) |
VISA |
|
|
Associated Research |
3605 |
Hypot |
No references required |
(NA) |
Manual |
|
|
Associated Research |
3665 |
Hypot |
No references required |
(NA) |
Manual |
|
|
Associated Research |
3670 |
Hypot |
No references required |
(NA) |
Manual |
|
|
Fluke |
10 |
3.5 Digit DMM |
Fluke |
(N/A) |
Manual |
|
|
Fluke |
11 |
3.5 Digit DMM |
Fluke |
(N/A) |
Manual |
|
|
Fluke |
12 |
3.5 Digit DMM |
Fluke |
(N/A) |
Manual |
|
|
Fluke |
12B |
3.5 Digit DMM |
Fluke |
(N/A) |
Manual |
|
|
Fluke |
18 |
3.5 Digit DMM |
Fluke |
(N/A) |
Manual |
|
|
Fluke |
8 |
3.5 Digit DMM |
Fluke |
(N/A) |
Manual |
|
|
Hewlett-Packard |
34970A |
Data Acquisition |
Fluke 5730A, Any Function Generator |
(N/A) |
IEEE-488 |
|
|
Keysight |
34972A |
Data Acquisition |
Fluke 5522A, Function Generator w/IEEE-488 Interface |
(1 year) |
VISA |
|
|
Keysight |
34972A |
Data Acquisition |
Fluke 5522A, Function Generator w/IEEE-488 Interface |
(N/A) |
VISA |
|
|
Hewlett-Packard |
34970A |
Data Acquisition |
Fluke 5730A, Any Function Generator |
(1 year) |
IEEE-488 |
|
|
LeCroy |
See Instrument Line in Main Procedure |
Not Determined |
Fluke 5520A |
(1 year) |
IEEE-488 |
|
|
LeCroy |
See Instrument Line in Main Procedure |
Not Determined |
Fluke 5800A |
(1 year) |
IEEE-488 |
|
|
LeCroy |
See Instrument Line in Main Procedure |
Not Determined |
Fluke 5820A |
(1 year) |
IEEE-488 |
|
|
LeCroy |
See Instrument Line in Main Procedure |
Not Determined |
Fluke 5500A |
(1 year) |
IEEE-488 |
|
|
LeCroy |
See Instrument Line in Main Procedure |
Not Determined |
Fluke 5820A |
(1 year) |
IEEE-488 |
|
|
LeCroy |
See Instrument Line in Main Procedure |
Not Determined |
Fluke 5820A |
(1 year) |
IEEE-488 |
|
|
LeCroy |
See Instrument Line in Main Procedure |
Not Determined |
Fluke 5820A |
(1 year) |
IEEE-488 |
|
|
Agilent |
33220A |
Function / Arbitrary Waveform Generator |
Fluke or Philips PM6680, Fluke 5790A w/WIdeband AC Option, Keysight Agilent or HP 3458A |
Adjustment |
IEEE-488 |
|
|
Agilent |
33220A |
Function / Arbitrary Waveform Generator |
Fluke or Philips PM6680, Fluke 5790A w/WIdeband AC Option, Fluke 8508A |
Adjustment |
IEEE-488 |
|
|
Agilent |
34401A |
DMM |
Fluke 5520A |
Adjustment (na) |
IEEE-488 |
|
|
Agilent |
34401A |
DMM |
Fluke 5522A |
Adjustment (na) |
IEEE-488 |
|
|
Agilent |
34401A |
DMM |
Fluke 5700A, Fluke 5725A |
Adjustment (na) |
IEEE-488 |
|
|
Agilent |
34401A |
DMM |
Fluke 5700A/EP or 5720A, Fluke 5725A |
Adjustment (na) |
IEEE-488 |
|
|
Agilent |
34401A |
DMM |
Fluke 5730A, Fluke 5725A |
Adjustment (na) |
IEEE-488 |
|
|
Agilent |
34401A |
DMM |
Fluke 5520A |
Adjustment (na) |
RS-232 |
|
|
Agilent |
34401A |
DMM |
Fluke 5522A |
Adjustment (na) |
RS-232 |
|
|
Agilent |
34405A |
DMM |
Fluke 5502A |
Adjustment |
VISA |
|
|
Agilent |
34405A |
DMM |
Fluke 5502E |
Adjustment |
VISA |
|
|
Agilent |
34405A |
DMM |
Fluke 5520A |
Adjustment |
VISA |
|
|
Agilent |
34405A |
DMM |
Fluke 5522A |
Adjustment |
VISA |
|
|
Agilent |
34410A |
DMM |
Fluke 5700A/EP 5720A or 5730A, Any Function Generator w/IEEE-488 |
Adjustment |
IEEE-488 |
|
|
Agilent |
34410A |
DMM |
Fluke 5730A, Any Function Generator w/IEEE-488 |
Adjustment |
IEEE-488 |
|
|
Agilent |
34411A |
DMM |
Fluke 5700A/EP 5720A or 5730A, Any Function Generator w/IEEE-488 |
Adjustment |
IEEE-488 |
|
|
Agilent |
34411A |
DMM |
Fluke 5730A, Any Function Generator w/IEEE-488 |
Adjustment |
IEEE-488 |
|
|
Agilent |
34460A |
DMM |
Fluke 5720A or 5700A/EP, Function Generator w/IEEE-488 interface |
Adjustment (N/A) |
VISA |
|
|
Agilent |
34460A |
DMM |
Fluke 5730A, Function Generator w/IEEE-488 interface |
Adjustment (N/A) |
VISA |
|
|
Agilent |
34461A |
DMM |
Fluke 5720A or 5700A/EP, Function Generator w/IEEE-488 interface |
Adjustment (N/A) |
VISA |
|
|
Agilent |
34461A |
DMM |
Fluke 5730A, Function Generator w/IEEE-488 interface |
Adjustment (N/A) |
VISA |
|
|
Agilent |
34970A |
Data Acquisition/Data Logger Switch Unit |
Fluke 5520A |
Adjustment (N/A) |
IEEE-488 |
|
|
Agilent |
34970A |
Data Acquisition/Data Logger Switch Unit |
Fluke 5522A |
Adjustment (N/A) |
IEEE-488 |
|
|
Agilent |
34970A |
Data Acquisition |
Fluke 5700A, Any Function Generator |
Adjustment (na) |
IEEE-488 |
|
|
Agilent |
34970A |
Data Acquisition |
Fluke 5720A, Any Function Generator |
Adjustment (na) |
IEEE-488 |
|
|
Agilent |
34970A |
Data Acquisition |
Fluke 5730A, Any Function Generator |
Adjustment (na) |
IEEE-488 |
|
|
Agilent |
34972A |
Data Acquisition/Data Logger Switch Unit |
Fluke 5520A |
Adjustment (N/A) |
VISA |
|
|
Agilent |
34972A |
Data Acquisition/Data Logger Switch Unit |
Fluke 5522A |
Adjustment (N/A) |
VISA |
We'd like your feedback.
You can help us improve our website »
Thank you!
Questions regarding Service, General Metrology, Certificates of Calibration or if you are in need of Technical Support can be submitted via our Support Request form.