Comparing the 5560A and 5522A Multi-Product Calibrators
In this video, Fluke Calibration Electrical/RF Product Program Manager, Bill Gaviria, provides a side-by-side comparison of the 5560A High Performance Multi-Product Calibrator and the older 5522A Multi-Product Calibrator.
Transcript
Hi, my name is Bill Gaviria. I am the Fluke Calibration Product Manager and I am here to introduce you to the next generation high-performance multi-product calibrator, the 5560A, and we’ll do a comparison to our predecessor, the 5522A.
In the new high-performance calibrator you will be able to calibrate six and a half digits DMMs to full manufacturer’s specifications at a four to one ratio, unlike our predecessor, the 5522 where you did not have that capability.
The displays are also a little bit more intuitive now. You’re able to scroll a lot faster, get to your measurement process a lot quicker, more drop-down menus, easier to manipulate, faster, it has a faster settling time.
In our latest generation calibrators we have introduced our Visual Management™ capability which refers to lighting up the terminals in which you need to make the connection. That allows you to go through a procedure with less mistakes, unlike the 5522 where common errors would occur due to the lack of visual management display.
The new high-performance calibrator also has additional features such as its temperature capability. It allows you to observe the temperature of the calibrator so that you can make a quantitative measurement whether your measurement is in tolerance within the temperature window or not.
The new 5560 will also be MET/CAL compatible. It will have a built-in FSC allowing you to continue to use MET/CAL and it will be released with several hundred of the most popular MET/CAL procedures in the market.
So with the 5560A, you have a four to one uncertainty, faster settling time, Visual Connection Management terminals, easy-to-use graphical interface, MET/CAL compatible … these are some of the major improvements that the 5560A has over the 5522A.
- Startseite
- Produkte
- Neue Produkte
- Elektrische Kalibrierung
- HF-Kalibrierung
- Datenerfassung und Testgeräte
- Temperaturkalibrierung
- Feuchtekalibrierung
- Druckkalibrierung
- Kolbenmessgeräte
- Controller/Kalibratoren
- Druckmonitore
- Druckwaagen
- Manuelle Kalibratoren und Monitore
- Handheld Pressure Calibrators
- Luftdaten-Kalibrierung
- Messgeräte zur Überwachung der Umgebungsbedingungen
- Druckkalibrierungszubehör
- Benutzerdefinierte Druckkalibriersysteme
- Software zur Druckkalibrierung
- Durchflusskalibrierung
- Prozesskalibratoren
- Kalibriersoftware
- Service und Support
- Alle Kalibriergeräte
- Hand-Messgeräte
- Kaufinfo
- Aktuelles
- Schulung/Veranstaltungen
- Literatur/Ausbildung
- Service/Unterstützung
- Service Request (RMA)
- Serviceprogramme
- Technischer Support
- Wissensbasis
- Akkreditierung
- Autorisierte Servicezentren
- Calibration Certificates
- Community Forum
- My MET/SUPPORT
- Produkthandbücher (Bedienungsanleitungen)
- Sicherheitsdatenblätter (SDS)
- Recyclingprogramm
- Safety, Service, and Product Notices
- Gewährleistungen
- Software-Downloads
- Über uns