Probe-to-Readout Adapter Guide
Probe-to-Readout Adapter Guide
An adapter may be required to connect a Fluke Calibration SPRT, PRT, RTD, or thermistor probe with a specific termination to a readout different than the original one. Use the following table to identify which adapter (if required) is needed. In the table, find the cell where the probe termination row intersects the readout column. For example, a probe with a type A termination connecting to a 1523/1524 Thermometer would require a 2388-P adapter.
In cases where an adapter is not available to connect a probe and readout combination, a custom probe adapter may be available on request. Please contact your Fluke sales representative regarding custom probe adapters.
See an application note with photos of the probe terminations and readouts.
Probe Termination | 1529 Chub-E4 | Black Stack modules 2560, 2561, 2563, 2567 |
1586A Super-DAQ with DAQ-STAQ |
1594/1595 Super Thermometer |
1523/1524 Thermometer |
1502A/04 Thermometer |
"A" INFO-CON DIN 6-pin (for 914X-X-P, 9190A-X-P) * | 2388-B,-G,-L,-M | 2388-B,-G,-J,-S | 2388-B,-G,-L,-M | 2388-B,-G,-J,-S | 2388-P | Connect directly * |
"B" bare wire | Connect directly | Connect directly or extend cable with 2571-S | Connect directly to DAQ-STAQ or extend cable with 2571-S to Ch001 | Connect directly or extend cable with 2571-S | 2373-LPRT | Custom ** |
"D" DIN 5-pin (for 1502A/1504 Tweener, 917X-X-R) | 2388-B,-G,-L,-M | 2388-B,-G,-J,-S | 2388-B,-G,-L,-M | 2388-B,-G,-J,-S | 2388-P | Connect directly * |
"G" gold pins | Connect directly | Connect directly or extend cable with 2571-S | Connect directly to DAQ-STAQ or extend cable with 2571-S to Ch001 | Connect directly or extend cable with 2571-S | 2373-LPRT | Custom ** |
"I" INFO-CON (for 1521/1522)* | Custom ** | 2373 | 2373 | 2373 | 2373-L21 | Custom ** |
"J" banana plugs | Custom ** | Connect directly or extend cable with 2571-S | Connect directly to Ch001 or extend cable with 2571-S to Ch001 | Connect directly or extend cable with 2571-S | 2373-LPRT | Custom ** |
"L" mini spade lugs | Connect directly | Not available | Connect directly to DAQ-STAQ or extend cable with 2571-S to Ch001 | Not available | 2373-LPRT | Custom ** |
"M" mini banana plugs | Connect directly | Not available | Connect directly to DAQ-STAQ or extend cable with 2571-S to Ch001 | Not available | 2373-LPRT | Not available |
"P" INFO-CON (for 1523/1524 *) | 2389-B,-G,-L,-M | 2389-B,-G,-J,-S | 2389-B,-G,-L,-M | 2389-B,-G,-J,-S | Connect directly or extend cable with 2389-P | Custom ** |
"S" spade lugs | Custom ** | Connect directly or extend cable with 2571-S | Connect directly to Ch001 or extend cable with 2571-S to Ch001 | Connect directly or extend cable with 2571-S | 2373-LPRT | Custom ** |
Mini-jack thermocouple | Connect directly | Not available | Connect directly to DAQ-STAQ | Not available | 2373-LTC |
* Probe coefficients stored in an INFO-CON connector will not transfer to the readout. They must be entered into the readout manually.
** A custom probe adapter is available on request. Contact your Fluke sales representative.
- Accueil
- Produits
- Nouveautés
- Étalonnage électrique
- Étalonnage RF
- Équipements de test et d'acquisition de données
- Étalonnage de la température
- Étalonnage d'humidité
- Étalonnage de pression
- Manomètres à piston
- Contrôleurs/Étalonneurs
- Moniteurs de pression
- Balances manométriques
- Étalonneurs et moniteurs manuels
- Handheld Pressure Calibrators
- Étalonnage de données d'air
- Moniteurs environnementaux
- Accessoires d'étalonnage de pression
- Systèmes d'étalonnage de pression personnalisés
- Logiciel d'étalonnage de pression
- Étalonnage de débit
- Outils d'étalonnage de process
- Logiciel d'étalonnage
- Service et assistance
- Tous les instruments d'étalonnage
- Instruments de mesure portables
- Où acheter
- Actualités
- Formation
- Littérature et de l'éducation
- Service et Support
- Service Request (RMA)
- Programmes d'assistance
- Assistance technique
- Base de connaissances
- Accréditations
- Centres de service agréés
- Calibration Certificates
- Community Forum
- My MET/SUPPORT
- Manuels des produits (manuels d'utilisation)
- Fiches de données de sécurité (FDS)
- Programme de recyclage
- Safety, Service, and Product Notices
- Garantie
- Téléchargements de logiciels
- Qui nous sommes