SPRT secondaires, PRT, capteurs de température 5626/5628

5626 Secondary SPRT, PRT, Temperature Sensors
5628 Secondary SPRT, PRT, Temperature Sensors
5626 Secondary SPRT, PRT, Temperature Sensors
5628 Secondary SPRT, PRT, Temperature Sensors
Demander un devis
  • Caractéristiques
  • Description
  • Spécifications
  • Modèles et Accessoires
  • Connaissance et l'Information

Étalons secondaires pour les températures élevées

  • Plage jusqu'à 661 °C
  • Répondent à tous les critères ITS-90 requis en termes de rapports de résistance
  • Dérive de la résistance au point triple < 20 mK après 500 heures à 661 °C
  • Précision étalonnée de ± 0,006 °C à 0 °C

Les étalons secondaires Fluke Calibration pour les températures élevées comblent le fossé entre les PRT secondaires abordables, mais à température limitée, et les SPRT à haute précision et plus onéreux.

Si vous utilisez des étalonneurs à blocs, des fours ou des points de température supérieurs aux températures normales des PRT (420 °C), ces deux PRT sont faits pour vous. En nominal, le modèle 5626 fait 100 Ω et le modèle 5628 fait 25,5 Ω. Ces deux instruments présentent une plage de températures de –200 à 661 °C. Ils proposent des étalons de travail ou de vérification appréciables pour les tâches d'étalonnage jusqu'au point de fusion de l'aluminium.

L'utilisation d'un PRT classique à des températures supérieures à 500 °C expose le platine à des risques de contamination. Si vous utilisez le PRT en tant qu'étalon d'étalonnage ou de référence, la contamination est un problème majeur. Les SPRT, plus chers et plus délicats, peuvent tolérer des températures supérieures, mais avec des risques plus grands pour l'instrument en raison des chocs, de la contamination ou d'une mauvaise manipulation. Les modèles 5626 et 5628 sont conçus de façon à réduire le risque de contamination grâce à l'utilisation d'une protection interne, sans altérer les performances.

Outre une durabilité et des performances de mesure adéquates, un PRT destiné à des applications secondaires doit bénéficier d'un prix de vente abordable. Les nouveaux PRT Fluke Calibration sont peu coûteux et s'accompagnent d'un étalonnage certifié. L'étalonnage est complété par des constantes ITS-90 et un tableau résistance/température.

Vérifiez la plage de températures, la stabilité et le prix ! Quel autre fabricant vous offre un tel degré de qualité, de performances et de valeur à ce prix ? Aucun !

Caractéristiques techniques 

TempératurePlage 

–200 à 661 °C 

Température de manipulation  

0 à 80 °C 

Résistance au point triple de l'eau 

5626 : 100 Ω (± 1 Ω)
5628 : 25,5 Ω (± 0,5 Ω) 

Resistance Ratio W(Ga)

W(302.9146K) ≥ 1.11807
α ≥ 0.003925

Précision étalonnée† (k = 2) 

± 0,006 à –200 °C
± 0,006 à 0 °C
± 0,015 à 420 °C
± 0,022 à 661 °C 

Stabilité 

5626 : ± 0,003 °C
5628 : ± 0,002 °C 

Dérive à long terme (k=2) 

5626 :  < 0,006 °C/100 heures à 661 °C
5628 : < 0,004 °C/100 heures à 661 °C 

Immersion 

Au moins 12,7 cm (recommandé) 

Gaine 

Inconel™ 600 

Fils de sortie 

PVC super flexible à 4 fils, 22 AGW 

Extrémité 

Cosses à fourche plaquées or, ou spécifier 

Dimensions 

6,35 mm de diamètre x 305 mm, 381 mm ou 508 mm en format standard ; longueurs personnalisées disponibles 

Étalonnage 

Étalonnages certifiés Fluke Calibration

†Inclut l'étalonnage et une dérive de 100 heures

Model Name Description
5626-12-X

PRT standard secondaire (0,25 po diam. x 12 po), 100 Ω, –200 à 661 °C

X = borne. Spécifiez « A » (INFO-CON pour 914X), « B » (fil nu), « D » (DIN 5 broches pour thermomètres Tweener), « G » (broches en or), « J » (fiches banane), « L » (mini cosses à fourche), « M » (mini fiches banane), « P » (INFO-CON pour 1523 ou 1524) ou « S » (cosses à fourche).

5626-15-X

PRT standard secondaire (0,25 po diam. x 15 po), 100 Ω, –200 à 661 °C

X = borne. Spécifiez « A » (INFO-CON pour 914X), « B » (fil nu), « D » (DIN 5 broches pour thermomètres Tweener), « G » (broches en or), « J » (fiches banane), « L » (mini cosses à fourche), « M » (mini fiches banane), « P » (INFO-CON pour 1523 ou 1524) ou « S » (cosses à fourche).

5626-20-X

PRT haute température, 100 Ω, 508 mm, boîtier inclus

X = borne. Spécifiez « A » (INFO-CON pour 914X), « B » (fil nu), « D » (DIN 5 broches pour thermomètres Tweener), « G » (broches en or), « J » (fiches banane), « L » (mini cosses à fourche), « M » (mini fiches banane), « P » (INFO-CON pour 1523 ou 1524) ou « S » (cosses à fourche).

5628-12-X

PRT standard secondaire (0,25 po diam. x 12 po), 25,5 Ω, –200 à 661 °C

X = borne. Spécifiez « A » (INFO-CON pour 914X), « B » (fil nu), « D » (DIN 5 broches pour thermomètres Tweener), « G » (broches en or), « J » (fiches banane), « L » (mini cosses à fourche), « M » (mini fiches banane), « P » (INFO-CON pour 1523 ou 1524) ou « S » (cosses à fourche).

5628-15-X

PRT standard secondaire (0,25 po diam. x 15 po), 25,5 Ω, –200 à 661 °C

X = borne. Spécifiez « A » (INFO-CON pour 914X), « B » (fil nu), « D » (DIN 5 broches pour thermomètres Tweener), « G » (broches en or), « J » (fiches banane), « L » (mini cosses à fourche), « M » (mini fiches banane), « P » (INFO-CON pour 1523 ou 1524) ou « S » (cosses à fourche).

5628-20-X

PRT haute température, 25,5 Ω, 508 mm, boîtier inclus

X = borne. Spécifiez « A » (INFO-CON pour 914X), « B » (fil nu), « D » (DIN 5 broches pour thermomètres Tweener), « G » (broches en or), « J » (fiches banane), « L » (mini cosses à fourche), « M » (mini fiches banane), « P » (INFO-CON pour 1523 ou 1524) ou « S » (cosses à fourche).

Accessories common to all models:

Accessoire Description
2609

Boîtier de rechange (pour TC de 635 mm de long)

Manuels de produits
application/pdf icon 5626/5628 Platinum Resistance Thermometer User’s Guide (438.46 Ko)
application/pdf icon 5626/5628 Platinum Resistance Thermometer User’s Guide (rus) (507.61 Ko)
Notes d'application
application/pdf icon Calculating Calibration Uncertainties in an Automated Temperature Calibration System (426.88 Ko)
application/pdf icon Establishment of a Secondary Temperature Calibration Laboratory (3.09 Mo)
application/pdf icon English: Thermocouple App Notes Series, 2 of 4 - How to Select Thermocouple Calibration Equipment (2.51 Mo)
application/pdf icon German: Thermocouple App Notes Series, 2 of 4 - Auswahl von Geräten zur Kalibrierung von Thermoelementen (2.21 Mo)
application/pdf icon French: Thermocouple App Notes Series, 2 of 4 - Guide de sélection d'équipement d'étalonnage de thermocouple (2.21 Mo)
application/pdf icon Russian: Thermocouple App Notes Series, 2 of 4 - Как выбрать оборудование для калибровки термопары (2.26 Mo)
application/pdf icon Spanish: Thermocouple App Notes Series, 2 of 4 - Cómo elegir un equipo de calibración de termopares (2.21 Mo)
application/pdf icon Industrial temperature readout and probe selection guide (1.06 Mo)
application/pdf icon Temperature Calibration Equipment: A Technician's Guide (1.62 Mo)
application/pdf icon Temperature measurement and calibration: What every instrument technician should know (1.65 Mo)
application/pdf icon Temperaturmessung und -kalibrierung (German) (650.54 Ko)
application/pdf icon Mesure et étalonnage thermique (French) (655.57 Ko)
application/pdf icon Medición y calibración de temperatura (Spanish) (651.42 Ko)
application/pdf icon English: Thermocouple App Notes Series, 1 of 4 - Thermocouple Fundamentals (2.5 Mo)
application/pdf icon Korean: 열전대 응용시리즈 첫번째 - 열전대의 기본사항 (2.28 Mo)
application/pdf icon German: Thermocouple App Notes Series, 1 of 4 - Grundlagen zu Thermoelementen (2.22 Mo)
application/pdf icon French: Thermocouple App Notes Series, 1 of 4 - L'essentiel des thermocouples (2.22 Mo)
application/pdf icon Spanish: Thermocouple App Notes Series, 1 of 4 - Nociones básicas de los termopares (2.22 Mo)
application/pdf icon Russian: Thermocouple App Notes Series, 1 of 4 - Основные сведения о термопаре (2.29 Mo)
application/pdf icon Why Use a Triple Point of Water? (1.19 Mo)
application/pdf icon Does Immersion Depth Really Matter? (745.44 Ko)
Articles
application/pdf icon A High-Quality Platinum Resistance Thermometer to 661°C (85.57 Ko)
application/pdf icon An Investigation of Long-Term Stability of a Precision Platinum Resistance Thermometer up to 660°C (164.52 Ko)
application/pdf icon Fixed Points for Secondary Level and Industrial Calibration (496.68 Ko)
application/pdf icon Fixed Points for Secondary Level Calibrations (560.12 Ko)
I Just Got My Probe Recalibrated, Now What?
application/pdf icon Improving the Stability of Standard Platinum Resistance Thermometers (207.37 Ko)
application/pdf icon Methods for Evaluating the Condition of Platinum Resistance Thermometers (130.23 Ko)
Platinum Resistance Thermometers (PRT)
application/pdf icon Proper Platinum Resistance Thermometer Calibration Uncertainty Analysis (351.32 Ko)
application/pdf icon Using a Mini Triple Point of Water System to Improve Reliability in a Temperature Calibration Laboratory (177.86 Ko)
Why did my temperature sensor fail calibration?
On-Demand Webinars
Overcoming Drift: Tips to Maintaining Your PRTs
  • Version imprimable »
  • Accueil
  • Produits
    • Nouveautés
    • Étalonnage électrique
      • Étalons électriques
      • Étalonneurs
      • Multimètres de table
      • Logiciel d'étalonnage électrique
    • Étalonnage RF
      • Sources de référence RF
      • Accessoires d'étalonnage RF
      • Logiciel d'étalonnage RF
    • Équipements de test et d'acquisition de données
      • Multimètres d'établi
      • Acquisition de données
      • Logiciel d'acquisition de données
    • Étalonnage de la température
      • Étalons primaires
        • Cellules à point fixe ITS-90
        • Thermomètres à résistance de platine standard (SPRT)
        • Appareil de maintenance
        • Étalonneur de comparaison de l'azote liquide
        • Ponts de résistance
        • Résistances standard
      • Bains d'étalonnage
        • Bains d'étalonnage compacts
        • Bains d'étalonnage standard
        • Bains pour application spéciale
        • Accessoires pour bain d'étalonnage
        • Contrôleurs de bain d'étalonnage
        • Fluides de bain d'étalonnage
      • Étalonneurs de température industriels
        • Puits de métrologie de terrain
        • Puits de métrologie
        • Étalonneurs à puits sec portatifs
        • Étalonneurs à bloc sec de terrain
        • Micro-bains
        • Étalonneurs infrarouges
        • Fours à thermocouple
        • Puits sec double bloc
        • Puits sec de point zéro
      • Sondes/Capteurs
        • Thermomètres à résistance de platine (PRT)
        • Thermistances
        • Thermocouples
      • Afficheurs thermométriques
      • Étalonneurs multifunction
      • Logiciel d'étalonnage de température
    • Étalonnage d'humidité
      • Générateurs d'humidité
      • Enregistreurs de données et moniteurs d'humidité
    • Étalonnage de pression
      • Manomètres à piston
        • Manomètres à piston pour les instituts nationaux de métrologie
        • Manomètres à piston absolus
        • Manomètres à piston pneumatiques haute pression
        • Manomètres à piston hydrauliques
        • Accessoires de manomètre à piston
      • Contrôleurs/Étalonneurs
        • Contrôleurs/Étalonneurs basse pression
        • Contrôleurs/étalonneurs de pression pneumatique
        • Contrôleurs/étalonneurs pneumatiques haute pression
        • Contrôleur/étalonneur hydraulique
      • Moniteurs de pression
        • Moniteurs basse pression
        • Manomètres numériques
        • Moniteurs de pression de référence
      • Balances manométriques
        • Balance manométrique pneumatique
        • Balances manométriques à huile
        • Balances manométriques à eau
        • Balances manométriques hydrauliques à haute pression
        • Accessoires de balance manométrique
      • Étalonneurs et moniteurs manuels
        • Étalonneurs de pression
        • Contrôle de pression pneumatique
        • Comparateurs/pompes de pression hydraulique
      • Handheld Pressure Calibrators
      • Étalonnage de données d'air
      • Moniteurs environnementaux
      • Accessoires d'étalonnage de pression
      • Systèmes d'étalonnage de pression personnalisés
      • Logiciel d'étalonnage de pression
    • Étalonnage de débit
      • Étalons de débit de gaz
      • Accessoires de débit de gaz
      • Étalon de débit gravimétrique primaire
      • Logiciel d'étalonnage de débit
    • Outils d'étalonnage de process
      • Calibrateurs de température
        • Calibrateurs de température à main
        • Calibrateurs à bloc sec et micro-bains
        • Thermomètres numériques de précision
        • Sondes de température
        • Calibrateurs infrarouges
        • Hygromètre avec fonction d'enregistrement de données
      • Étalonneurs de pression
        • Calibrateurs numériques de pression
        • Calibrateurs de pression portable
        • Balances manométriques
        • Manomètres numériques de précision
        • Pompes manuelles d'étalonnage
      • Étalonneurs multifunction
      • Calibrateurs de boucle mA
      • Logiciel d'étalonnage de process
    • Logiciel d'étalonnage
      • Logiciel MET/CAL
      • Support MET/CAL
      • Logiciel de gestion des ressources
      • Logiciel d'étalonnage de température
      • Logiciel d'étalonnage de pression
      • Logiciels d'étalonnage de débit
      • Logiciel d'étalonnage mécanique/dimensionnel
    • Service et assistance
    • Tous les instruments d'étalonnage
    • Instruments de mesure portables
  • Où acheter
    • Où acheter
    • Demander un devis
    • Demander une démonstration
    • Demander une consultation de vente
    • Certified Pre-Owned Equipment
    • General Services Administration (GSA)
    • Financing Program
    • National Stock Numbers (NSNs)
    • Payment Options and Tax Info
  • Actualités
    • Communiqués de presse
    • Promotions
    • Liens industriels
    • Metrology Salary Survey
  • Formation
    • Conférences et expositions
    • Cours dans Etats-Unis
    • User Group Meetings
    • Séminaires en ligne
      • Séminaires en direct
      • Séminaires à la demande
  • Littérature et de l'éducation
    • Education Hub
    • About Calibration
    • Articles et éducation
    • Documentation des produits
    • Manuels des produits (manuels d'utilisation)
    • Vidéos et démos virtuelles
    • Centres de ressources
    • Blog
  • Service et Support
    • Service Request (RMA)
    • Programmes d'assistance
    • Assistance technique
    • Base de connaissances
    • Accréditations
    • Centres de service agréés
    • Calibration Certificates
    • Community Forum
    • My MET/SUPPORT
      • Activate
      • Procedures
      • Software
      • Technical Bulletins
      • Priority Support
      • Manuals
    • Manuels des produits (manuels d'utilisation)
    • Fiches de données de sécurité (FDS)
    • Programme de recyclage
    • Safety, Service, and Product Notices
    • Garantie
    • Téléchargements de logiciels
  • Qui nous sommes
    • Nous contacter
    • Nous rendre visite
    • Carrières Fluke
    • Fluke Calibration
      • Étalonnage de la température Hart Scientific
      • Étalonnage du débit et de la pression DH Instruments
      • Étalonnage de la pression Pressurements
      • Étalonnage de la pression Ruska
    • Entreprises Fluke
    • Intégrité et conformité
    • Foire aux questions
    • Pourquoi choisir Fluke Calibration ?
Accueil|Produits|Étalonnage de la température|Sondes/Capteurs|Thermomètres à résistance de platine (PRT)|SPRT secondaires, PRT, capteurs de température 5626/5628

Sidebar Request a Quote

Demander un devis

Oui, je souhaite recevoir les actualités, les conseils, les formations et d’autres informations par e-mail de la part de Fluke Calibration.

©1995-2023 Fluke Corporation
             

Secondary menu

  • Disclaimer
  • Déclaration de confidentialité
  • Terms of Use
  • Conditions de Vente