Very stable thermometer from –200 °C to 670 °C
- 5608: –200 °C to 500 °C (80 mm minimum immersion)
- 5609: –200 °C to 670 °C (100 mm minimum immersion)
- NVLAP-accredited calibration, lab code 200348-0
- Dry-well reference with 90 ° bend
If you want a very stable thermometer from –200 °C to 670 °C and are particular about the calibration, then look no further than our 5609 Secondary Reference PRT. Its short-term stability at the triple point of water is only ± 7 mK and its one-quarter inch (6.23mm) diameter lets you get accurate measurements in only 100 mm of immersion.
The 5608 is also a ± 7 mK probe at the triple point of water, but its one-eighth inch (3.18 mm) diameter gets you accurate measurements from –200 °C to 500 °C with only 80mm (3.1 in) of immersion. With multiple sheath length options on both of these probes, you can find the dimensions that are just right for your specific application.
The 5608 comes with a one-eighth inch (3.18 mm) diameter sheath in lengths of 9 inches or 12 inches. The 5609 comes with a one-quarter inch (6.35 mm) diameter sheath in lengths of 12 inches, 15 inches, and 20 inches; or with a 6 mm diameter in lengths of 300 mm, 400 mm, or 500 mm.
When looking for improved response time and reduced stem effect in shallow immersion, look for small diameter probes, because the measurement error called stem effect is caused by the diameter of the stem rather than the length of the stem.
Both of these probes have Inconel™ sheaths and are made using a special manufacturing process, giving them great precision over a wide temperature range. The sensors for these probes are reference-grade platinum and feature four-wire connections with less noisy measurements than two-wire counterparts.
On the report of calibration, you’ll get the test data and the ITS90 calibration coefficients that you can easily input into any Fluke Calibration thermometer. If you order your probe with an smart connector, we’ll program the coefficients directly into your connector, which loads the coefficients for you when you plug it into our 1524 Handheld Thermometer.
Specifications |
|||||||||||||||||||||||
Temperature range |
5608: –200 °C to 500 °C 5609: –200 °C to 670 °C |
||||||||||||||||||||||
Nominal resistance at 0.01 °C | 100 Ω ± 0.5 Ω | ||||||||||||||||||||||
Temperature coefficient | 0.0039250 Ω/Ω/°C | ||||||||||||||||||||||
Relative Accuracy[1] |
± 0.007 °C at –200 °C ± 0.008 °C at 0 °C ± 0.020 °C at 420 °C ± 0.027 °C at 660 °C |
||||||||||||||||||||||
Short-term repeatability[2] |
± 0.007 °C at 0.010 °C ± 0.013 °C at max temp |
||||||||||||||||||||||
Drift[3] |
± 0.01 °C at 0.010 °C ± 0.02 °C at max temp |
||||||||||||||||||||||
Hysteresis | ± 0.01 °C maximum | ||||||||||||||||||||||
Sensor length | 30 mm ± 5 mm (1.2 in ± 0.2 in) | ||||||||||||||||||||||
Sensor location | 3 mm ± 1 mm from tip (0.1 in ± 0.1 in) | ||||||||||||||||||||||
Sheath material | Inconel™ 600 | ||||||||||||||||||||||
Minimum insulation resistance |
5608: 500 MΩ at 23 °C, 20 MΩ at 500 °C 5609: 500 MΩ at 23 °C, 10 MΩ at 670 °C |
||||||||||||||||||||||
Transition junction temperature range[4] | –50 ºC to 200 °C |
||||||||||||||||||||||
Transition junction dimensions | 71 mm x 12.5 mm (2.8 in x 0.49 in) | ||||||||||||||||||||||
Minimum immersion length[5] (<5 mK error) |
5608: 80 mm (3.1 in) 5609: 100 mm (3.9 in) |
||||||||||||||||||||||
Maximum immersion length | 305 mm (12 in) | ||||||||||||||||||||||
Response time[5] |
5608: 9 seconds typical 5609: 12 seconds typical |
||||||||||||||||||||||
Self heating (in 0 °C bath) |
5608: 75 mW/°C 5609: 50 mW/°C |
||||||||||||||||||||||
Lead-wire cable type | PTFE 24 AWG | ||||||||||||||||||||||
Lead-wire length | 1.8 m (6 ft) | ||||||||||||||||||||||
Lead-wire temperature range | –50 °C to 250 °C | ||||||||||||||||||||||
Calibration |
|
||||||||||||||||||||||
[1] Includes short-term repeatability and 100 hr drift. Calibration will add additional uncertainties. [2] Three thermal cycles from min to max temp, includes hysteresis, 99.9 % confidence (k=3) [3]After 100 hours at max temp, 99.9 % confidence (k=3) [4] Temperatures outside this range will cause irreparable damage. For best performance, transition junction should not be too hot to touch. [5] Per ASTM E 644 |
|
Model Name | Description |
---|---|
5608-9-X |
Secondary Reference PRT, 9 in x 1/8 in, –200 to 500 °C, lead wire (cable) 6 ft X = termination. Specify “A" (INFO-CON for 914X), “B" (bare wire), “D" (5-pin DIN for Tweener Thermometers), “G" (gold pins), “J" (banana plugs), “L" (mini spade lugs), “M" (mini banana plugs), “P" (INFO-CON for 1523 or 1524), or “S" (spade lugs). |
5608-12-X |
Secondary Reference PRT, 12 in x 1/8 in, –200 to 500 °C, lead wire (cable) 6 ft X = termination. Specify “A" (INFO-CON for 914X), “B" (bare wire), “D" (5-pin DIN for Tweener Thermometers), “G" (gold pins), “J" (banana plugs), “L" (mini spade lugs), “M" (mini banana plugs), “P" (INFO-CON for 1523 or 1524), or “S" (spade lugs). |
5609-12-X |
Secondary Reference PRT, 12 in x 1/4 in, –200 to 670 °C, lead wire (cable) 6 ft X = termination. Specify “A" (INFO-CON for 914X), “B" (bare wire), “D" (5-pin DIN for Tweener Thermometers), “G" (gold pins), “J" (banana plugs), “L" (mini spade lugs), “M" (mini banana plugs), “P" (INFO-CON for 1523 or 1524), or “S" (spade lugs). |
5609-20-X |
Secondary Reference PRT, 20 in x 1/4 in, –200 to 670 °C, lead wire (cable) 6 ft X = termination. Specify “A" (INFO-CON for 914X), “B" (bare wire), “D" (5-pin DIN for Tweener Thermometers), “G" (gold pins), “J" (banana plugs), “L" (mini spade lugs), “M" (mini banana plugs), “P" (INFO-CON for 1523 or 1524), or “S" (spade lugs). |
5609-300-X |
Secondary Reference PRT, 300 mm x 6 mm, –200 to 670 °C, lead wire (cable) 6 ft X = termination. Specify “A" (INFO-CON for 914X), “B" (bare wire), “D" (5-pin DIN for Tweener Thermometers), “G" (gold pins), “J" (banana plugs), “L" (mini spade lugs), “M" (mini banana plugs), “P" (INFO-CON for 1523 or 1524), or “S" (spade lugs). |
5609-400-X |
Secondary Reference PRT, 400 mm x 6 mm, –200 to 670 °C, lead wire (cable) 6 ft X = termination. Specify “A" (INFO-CON for 914X), “B" (bare wire), “D" (5-pin DIN for Tweener Thermometers), “G" (gold pins), “J" (banana plugs), “L" (mini spade lugs), “M" (mini banana plugs), “P" (INFO-CON for 1523 or 1524), or “S" (spade lugs). |
5609-500-X |
Secondary Reference PRT, 500 mm x 6 mm, –200 to 670 °C, lead wire (cable) 6 ft X = termination. Specify “A" (INFO-CON for 914X), “B" (bare wire), “D" (5-pin DIN for Tweener Thermometers), “G" (gold pins), “J" (banana plugs), “L" (mini spade lugs), “M" (mini banana plugs), “P" (INFO-CON for 1523 or 1524), or “S" (spade lugs). |
5609-9BND |
Secondary Reference PRT, 15 in x 1/4 in, 9 in bend, –200 °C to 670 °C, lead wire (cable) 6 ft X = termination. Specify “A" (INFO-CON for 914X), “B" (bare wire), “D" (5-pin DIN for Tweener Thermometers), “G" (gold pins), “J" (banana plugs), “L" (mini spade lugs), “M" (mini banana plugs), “P" (INFO-CON for 1523 or 1524), or “S" (spade lugs). |
Accessories common to all models:
Accessory | Description |
---|---|
2601 |
Probe Carrying Case, Plastic (for probes up to 228 mm [9 in] in length) |
2609 |
Probe Carrying Case, Plastic (for probes 635 mm [25 in] in length) |
1930-4-R |
System Calibration by Comparison for 5608 and 5609 PRTs, -200 °C to 500 °C, NVLAP Accredited (probe and thermometer readout combined as a system) |
1930-4-7 |
System Calibration by Comparison for 5609 PRTs, -200 °C to 660 °C, NVLAP Accredited (probe and thermometer readout combined as a system) |
Product Manuals |
---|
Application Notes |
---|
Data Sheets |
---|
Papers / Articles |
---|
I Just Got My Probe Recalibrated, Now What? |
Platinum Resistance Thermometers (PRT) |
- Home
- Products
- New Products
- Electrical Calibration
- RF Calibration
- Data Acquisition and Test Equipment
- Temperature Calibration
- Humidity Calibration
- Pressure Calibration
- Flow Calibration
- Process Calibration Tools
- Calibration Software
- Service and Support
- All Calibration Instruments
- Handheld Test Tools
- Purchase Info
- News
- Training and Events
- Literature and Education
- Service and Support
- Service Request (RMA)
- Service Plans
- Technical Support
- Knowledge Base
- Accreditations
- Authorized Service Centers
- Calibration Certificates
- Community Forum
- My MET/SUPPORT
- Product Manuals (User Guides)
- Safety Data Sheets (SDS)
- Recycle Program
- Safety, Service, and Product Notices
- Software Downloads
- Warranties
- Tools
- About Us
Sidebar Request a Quote
Request a quote