- Other Fluke companies:
- Fluke
- Fluke Biomedical
- Fluke Networks
- Fluke Process Instruments
PPC4 - Redefining premium performance in a digital pressure calibrator or portable pressure calibrator
|
And still delivering:
|
From the cal lab bench top to 24/7 fully automated production testing, there’s a PPC4™ digital pressure calibrator configuration perfect for your pressure transducer calibration application.
|
For applications that require less accuracy or wider pressure range coverage, see the Fluke Calibration 6270A Modular Pressure Controller/Calibrator ».
The basic and advanced PPC4 includes all the pressure transducer calibration features you expect in a state-of-the-art digital pressure calibrator
|
PPC4 General Specifications |
|
Power requirements | 100 to 240 VAC 50/60 Hz, 70 W max consumption |
Operating temperature range | 15 to 40 °C (50 °F to 104 °F) |
Storage temperature range | - 20 to 70 °C (-4 °F to 158 °F) |
Vibration | Meets MIL-T-28800D |
Weight | 16.6 kg (36.5 lb) |
Dimensions | |
PPC4: | 19 cm H x 35 cm W x 41 cm D (7.5 in. x 13.8 in. x 16.1 in.) |
PPC4-ui: | 19 cm H x 35 cm W x 45 cm D (7.5 in. x 13.8 in. x 17.7 in.) |
Remote communication interfaces | RS232 (COM1, COM2), USB (front panel) Optional: IEEE-488.2 or Ethernet and USB (Rear Panel) |
Languages Supported (Advanced UI) | Chinese (simplified), Chinese (traditional), Czech, English, French, German, Italian, Japanese, Portuguese, Russian and Spanish |
Pressure ranges | Vacuum to 14 MPa (2,000 psi) |
Operating medium | Any clean, dry, non-corrosive gas |
Supply pressure | Maximum desired set pressure + 70 kPa (10 psi) |
Exhaust pressure | Atmosphere or vacuum for pressures under 5 psig (35 kPa gauge) |
Pressure connections | |
TEST (+), TEST (-): | 1/8 in. NPT F |
SUPPLY: | 1/8 in. NPT F |
EXHAUST: | 3/8 in. NPT F |
ATM: | 10-32 UNF |
Pressure limits | |
Maximum working test pressure: | 103% Hi Q-RPT maximum |
Maximum pressure on TEST port without damage: | 115 % Hi Q-RPT maximum |
Utility sensor (if present) | |
Resolution: | 0.001% of span |
Precision: | 0.1% of span |
Pressure measurement |
|
Warm up time | 30 minute temperature stabilization recommended for best performance from cold power up. |
Resolution | To 1 ppm, user adjustable |
Acceleration affect | ± 0.008 % /g maximum, worst axis. Allows operation at ± 20° from reference plane without significant effect. |
Predicted one year stability1 | ± 0.005% of reading (Gauge mode or Absolute mode with regular use of AutoZero) |
Precision2 | Full Scale Standard Q-RPT Class ± 0.01 % of AutoRanged span4 Standard Q-RPT Class ± 0.008 % of reading5 Premium Q-RPT Class ± 0.005 % of reading7 |
Measurement Uncertainty3 | Full Scale Standard Q-RPT Class ± 0.015 % of AutoRanged span4 Standard Q-RPT Class ± 0.01 % of reading6 Premium Q-RPT Class ± 0.008 % of reading8 |
1 Predicted Q-RPT measurement stability limit (k=2) over one year assuming regular use of AutoZero function. AutoZero occurs automatically in gauge mode whenever vented, by comparison with barometric reference in absolute mode. Absolute mode predicted one year stability without AutoZ is ± (0.005 % Q-RPT span + 0.005 % of reading).
2 Combined linearity, hysteresis, repeatability. Add + 1 Pa (0.00015 psi) in gauge mode with an Axxx (absolute) Q-RPT for the resolution and short term stability of the on-board barometer.
3 Maximum deviation of the Q-RPT indication from the true value of applied pressure including precision, predicted one year stability limit, temperature effect and calibration uncertainty, combined and expanded (k=2) following the ISO “Guide to the Expression of Uncertainty in Measurement.
4 % of AutoRanged span, but with AutoRanged span no lower than 30 % of Q-RPT span (10 % with BG15K and G15K).
5 ±0.008 % of reading from 30 % to 100 % of Q-RPT span. Below 30 %; ±0.0024 % of Q-RPT span.
6 ±0.01 % of reading from 30 % to 100 % of Q-RPT span. Below 30 %; ±0.0030 % of Q-RPT span.
7 ±0.005 % of reading from 30 % to 100 % of any AutoRanged span between 30 % and 100 % of maximum Q-RPT span. Below 30 %; ±0.0015 % of AutoRanged span, or 0.0005 % of Q-RPT span, whichever is greater.
8 ±0.008 % of reading from 30 % to 100 % of any AutoRanged span between 30 % and 100 % of maximum Q-RPT span. Below 30 %; ±0.0024 % of AutoRanged span, or 0.0007 % of Q-RPT span, whichever is greater.
Note: Technical note 8050TN11 provides a detailed description of PPC4 Q-RPT uncertainties.
Pressure Control Modes and Ready Indication |
|
Static mode | Sets pressure to target within hold limit and shuts off control in a closed test volume. Pressure is “ready when inside hold limit and stability test is met. |
Dynamic mode | Sets pressure within hold limit and continuously adjusts pressure to remain at target value. Pressure is “ready when inside hold limit. |
Control parameters | Hold limit, stability limit (default values can be adjusted by user) |
Pressure Control Performance |
|
Control precision | ± 4 ppm of Q-RPT span or ± 0.4 ppm of HI Q-RPT span, whichever is greater. |
Lowest controllable pressure in dynamic mode | Gauge: Zero set by automated venting. Lowest point above or below zero limited only by Q-RPT resolution and control precision. Absolute, negative gauge: ±0.05% of Q-RPT span or 1 kPa (0.15 psia), whichever is greater |
Ultimate pressure (absolute, negative gauge) |
With low ultimate pressure option: 50 Pa (0.5 mbar, 0.007 psia) typical, depending on vacuum pump and connections Without low ultimate pressure option: 200 to 700 Pa (2 to 7 mbar, 0.03 to 0.1 psia) depending on vacuum pump and connections |
Typical pressure setting ready time (0.005 % hold limit, 50 cc test volume) | 15 to 35 s |
Slew time (ATM to FS with 50 cc test volume) |
30 s |
Typical test volume | HI Q-RPT span: 0-2 MPa [0-300 psi]: 0-1,000 cc HI Q-RPT span: 3.5-14 MPa [500-2000 psi]: 0-500 cc |
Model Name | Description | |
---|---|---|
PPC4-ui xxxxy/zzzzy |
PPC4 Controller/Calibrator with Advanced user interface (color display, full keypad, point-and-click knob) To configure:
For detailed information about configuration options, download the PPC4 product brochure. |
|
PPC4 xxxxy/zzzzy |
PPC4 Controller/Calibrator with Basic user interface (2 x 20 character, 10 key) To configure:
For detailed information about configuration options, download the PPC4 product brochure. |
Accessories common to all models:
Accessory | Description |
---|---|
A1.4M |
PPC4 Quartz Reference Pressure Transducer (Q-RPT) US Version |
A100K |
PPC4 Quartz Reference Pressure Transducer (Q-RPT) SI Version US Version |
A10M |
PPC4 Quartz Reference Pressure Transducer (Q-RPT) SI Version US Version |
A14M |
PPC4 Quartz Reference Pressure Transducer (Q-RPT) US Version |
A160K |
PPC4 Quartz Reference Pressure Transducer (Q-RPT) SI Version US Version |
A200K |
PPC4 Quartz Reference Pressure Transducer (Q-RPT) SI Version US Version |
A2M |
PPC4 Quartz Reference Pressure Transducer (Q-RPT) US Version |
A3.5M |
PPC4 Quartz Reference Pressure Transducer (Q-RPT) SI Version US Version |
A350K |
PPC4 Quartz Reference Pressure Transducer (Q-RPT) SI Version US Version |
A700K |
PPC4 Quartz Reference Pressure Transducer (Q-RPT) SI Version US Version |
A7M |
PPC4 Quartz Reference Pressure Transducer (Q-RPT) SI Version US Version |
BA100K |
PPC4 Quartz Reference Pressure Transducer (Q-RPT) SI Version US Version |
BG15K |
PPC4 Quartz Reference Pressure Transducer (Q-RPT) SI Version US Version |
G100K |
PPC4 Quartz Reference Pressure Transducer (Q-RPT) SI Version US Version |
G15K |
PPC4 Quartz Reference Pressure Transducer (Q-RPT) SI Version US Version |
G200K |
PPC4 Quartz Reference Pressure Transducer (Q-RPT) SI Version US Version |
RS232 |
9 pin, 2m for PPC4E COM1 |
BAS-SITE |
BAS-SITE COMPASS® for Pressure Software Enhanced, Site License |
BAS-SNGL |
BAS-SNGL COMPASS® for Pressure Software Basic, Single User |
ENH-SNGL |
ENH-SNGL COMPASS® for Pressure Software Enhanced, Single User |
PK-PPC-BG-DVU |
Dual volume unit for use with BG15K Q-RPT |
Reference vacuum kit, 110V |
VA-PPC/MPC-REF, 110V Vacuum pump package for PPC EXHAUST port |
Reference vacuum kit, 220V |
VA-PPC/MPC-REF, 220V Vacuum pump package for PPC EXHAUST port (220V) |
RPM4 |
Reference pressure monitor for external Q-RPTs and/or absolute mode AutoZ. |
SPLT |
Self purging liquid trap for PPC4 TEST port |
Priority Gold Instrument CarePlan |
Fluke Calibration Priority Gold Instrument CarePlans are available for most calibration products. Please contact your local Fluke Calibration sales representative for details or to request a quote. You may also call the Customer Care Center at 800-882-6153 or send email to premiumcare@fluke.com. |
Silver CarePlan |
Fluke Calibration Silver CarePlans are available for most calibration products. Please contact your local Fluke Calibration sales representative for details or to request a quote. You may also call the Customer Care Center at 877-355-3225 or send email to careplans@flukecal.com. |
Product Manuals |
---|
PPC4 Cockpit Sample Run Windows |
Brochures |
---|
Application Notes |
---|
Software |
---|
COMPASS for Pressure Calibration Software Download/Upgrade |
Firmware |
---|
PPC4 v1.2.6.14 Embedded Software |
Instruction Sheets |
---|
Free Utilities |
---|
CalTool for RPTs Free Utility |
CI Editor PC Based Free Utility |
- Home
- Products
- New Products
- Electrical Calibration
- RF Calibration
- Data Acquisition and Test Equipment
- Temperature Calibration
- Humidity Calibration
- Pressure Calibration
- Flow Calibration
- Process Calibration Tools
- Calibration Software
- Service and Support
- All Calibration Instruments
- Handheld Test Tools
- Purchase Info
- News
- Training and Events
- Literature and Education
- Service and Support
- Service Request (RMA)
- Service Plans
- Technical Support
- Knowledge Base
- Accreditations
- Authorized Service Centers
- Calibration Certificates
- Community Forum
- My MET/SUPPORT
- Product Manuals (User Guides)
- Safety Data Sheets (SDS)
- Recycle Program
- Safety, Service, and Product Notices
- Software Downloads
- Warranties
- Tools
- About Us
Sidebar Request a Quote
Request a quote