- Other Fluke companies:
- Fluke
- Fluke Biomedical
- Fluke Networks
- Fluke Process Instruments
Excellent rangeability and stability for pressure instrument calibration
Autoranging from ±1 kPa (0.15 psi) to 14 MPa (2,000 psi) ±0.02 % of span
The PPC4E pressure gauge calibrator demonstrates high performance in a variety of pneumatic pressure calibration conditions, including calibration laboratories, production sites, and sales field calibration conditions. Upgrade to the recognized stability and precision of PPC pressure control/calibrators with outstanding value and return on investment.
PPC4E combines the best features, measurement technology and patented PPC hydraulic controllers from our PPC4 family of controllers/calibrators to provide a wide pressure range at performance levels for your most common calibration loads. Calibration of transmitters, transducers, analog and digital instruments is possible through automation via a color graphical user interface or remote connection to a PC. PPC4E makes it incredibly easy to ensure the performance and uncertainty required for the calibration of all your pressure gauges. PPC4E instantly sets multiple parameters to achieve optimal precision, safety and measurement performance within the pressure range. Users simply enter the range and error into the device under test. The following measurement uncertainty in PPC4E is the percentage of the range that aligns with the UUT range, resulting in an easy-to-understand accuracy ratio.
Rangeability of PPC4E models
Models are called PPC4E or PPC4EX depending on whether they have one or two internal reference pressure transducers and the minimum autoranging span required to maintain the calibrator's optimal measurement uncertainty. Nominal measurement uncertainty is ±0.02
% of autoranging span to 10% for PPC4E and 1% for PPC4EX of
controller span. Refer to PPC4E measurement specifications for specific specifications. Fluke Calibration provides complete and reliable product measurement uncertainty specifications and full justification, and is valid for one year.
Features at a glance
- You will be satisfied with the one-year measurement specification, which allows for convenient use with switching between absolute, gauge and bidirectional meter modes without additional hardware, special calibration or maintenance work.
- Control pressures between 1 kPa (0.15 psi) and 14 MPa (2,000 psi) absolute or instrument equivalent, including ultra-low differential pressures.
- Perform accurate measurements and control range turndown up to 100:1 with a single calibrator.
- Autoranging optimizes measurement, control, and safety functions for the test you are running with just a few easy inputs.
- Built-in valve driver for ATE system designs with RS-232 and IEEE-488.2 remote interfaces
- An optional self-purifying liquid trap accessory protects the PPC4E from system contamination.
- Measurement uncertainty is calculated in real time and displayed in current pressure units.
- On-board programmable calibration sequences and leak test routines
- Quickly perform basic point intersection of analog instruments with set point jog function
- Standard color GUI supporting 11 languages
Precise control and low uncertainty over the entire PPC4E range
The PPC4E can replace two or more pressure controllers. There is no need for two independent control modules for PPC4E. In the lower range, controllers up to 10 times tighter and with control accuracy better than ±0.0006% of span ensure the boxes take full advantage of precision even during typical dynamic control operations. The PPC4E's Quartz sensor technology surpasses other control/calibrators in its class. PPC4E delivers the range and precision you need in a single interface, single test port.
Easy-to-use and informative UI
When operating PPC4E with a local user interface, you can instantly optimize all key settings and variables for the range and accuracy of the UUT with a few simple clicks and an auto-ranging feature. Operators can easily perform common calibration tasks without any special training or experience.
PPC4E allows you to quickly set up and run tests, and you can also create and save tests to load and run later. The “jog” function allows you to manually adjust the pressure at each target point to cause the UUT to measure the underlying target pressure, which is useful when calibrating analog instruments. During a test sequence, pressure measurements from the PPC4E corresponding to each UUT base point can be recorded and displayed in reporting. The uncertainty of the measured or supplied pressure is continuously calculated and displayed in PPC4E. The calculation at this time is based on the uncertainty factors of the PPC4E specification, and the user can adjust the values of each factor as desired.
COMPASS® software for automation
PPC4E is ready for integration into fully automated test systems. Rear panel RS-232 and IEEE-488.2 interfaces allow communication with remote computers. Remote operation is possible with a number of convenient and well-documented commands.
Pressure calibration software is automation support software that prevents engineering resources from being spent on creating separate automation software. COMPASS for Pressure is powerful and flexible enough to automate all elements of testing, including test execution, data collection, and reporting for benchtop calibration systems and multi-function sensor testing.
We also offer integrated turnkey calibration systems ranging from mobile carts to small footprint rack systems to pressure generation control and data acquisition hardware solutions.
PPC4E General Specifications |
|
Preheating time | Not required, 30 minutes of temperature stabilization recommended when running from complete stop |
Resolution | Can be set up to 1 ppm |
Power Requirements | 100 to 240 VAC (-15%, +10%), 50-60 Hz, 70 VA maximum consumption |
Operating temperature range: | 10 ~ 40 °C |
weight | 16.6 kg (36.5 lb) |
size | Height 19 cm x 35 cm Width x 45 cm Depth (7.5 in. x 13.8 in. x 17.7 in.) |
remote communication interface | RS232 (COM1, COM2), IEEE-488.2, USB (front panel firmware loading only) |
action medium | Clean, dry, non-corrosive gas |
pressure connection | |
TEST (+), TEST (-): | 1/8 in. NPT F |
offer: | 1/8 in. NPT F |
EXHAUST: | 3/8 in. NPT F |
ATM: | 10-32 UNF |
PPC4E Measurement uncertainty (including precision and 1-year accuracy) 1,2 |
|
PPC4EX 14M | Gauge uncertainty 1,3 % autoranging span: 0.02 Minimum autoranging span [kPa] 2 : 140 Absolute uncertainty 1.4 |
PPC4E 14M | Gauge uncertainty 1,3 % autoranging span: 0.02 Minimum autoranging span [kPa] 2 : 1400 Absolute uncertainty 1.4 % autoranging span: 0.02 Constant [kPa]: 1 Minimum autoranging span [kPa] 2 : 1400 |
PPC4EX 7M | Gauge uncertainty 1,3 % autoranging span: 0.02 Minimum autoranging span [kPa] 2 : 70 Absolute uncertainty 1.4 |
PPC4E 7M | 게이지 불확도1,3 % 자동범위 설정 스팬: 0.02 최소 자동범위설정 스팬 [kPa]2: 700 절대 불확도1.4 |
PPC4EX 1.4M | 게이지 불확도1,3 % 자동범위 설정 스팬: 0.02 최소 자동범위설정 스팬 [kPa]2: 14 절대 불확도1.4 |
PPC4E 1.4M | 게이지 불확도1,3 % 자동범위 설정 스팬: 0.02 최소 자동범위설정 스팬 [kPa]2: 140 절대 불확도1.4 |
PPC4EX 100K | 게이지 불확도1,3 % 자동범위 설정 스팬: 0.02 최소 자동범위설정 스팬 [kPa]2: ± 1 절대 불확도1.4 |
PPC4EX 100K | 게이지 불확도1,3 % 자동범위 설정 스팬: 0.02 최소 자동범위설정 스팬 [kPa]2: ± 10 절대 불확도1.4 |
PPC4E 15K | 게이지 불확도1,3 % 자동범위 설정 스팬: 0.02 최소 자동범위설정 스팬 [kPa]2: ± 1.5 |
- 정밀도, 예측 1년 안정도 한계, 발열효과와 교정 불확도를 ISO “측정 불확도의 표현에 대한 안내”에 따라 조합하고 확장 (k=2)한 적용 압력 참값으로부터 RPT 지시 값의 최대 오차.
- 최소 자동범위설정 스팬 이하의 자동범위설정 스팬의 경우 불확도는 최소 자동범위설정 스팬과 같음
- 계기 불확도는 자동범위설정 스팬의 %로 나타납니다. 예를 들어 PPC4E 7M 모델에서 3, 500kPa의 자동범위설정 스팬은 (0.02% * 3500kPa) = 0.35kPa 의 불확도를 가집니다.
- 절대 불확도는 자동범위설정 스팬 %과 영점 드리프트 보정 상수의 합입니다. 예를 들어 PPC4EX 100k 모델에서 80kPa의 자동범위설정 스팬은 (0.02% * 80kPa + 0.014kPa) = 0.03kPa 의 불확도를 가집니다.
온-보드 공압계
온-보드 공압계는 PPC4E 15k 이외 PPC4E 모델의 계기 측정 모드에서 대기압의 변화를 측정하여 절대 모드의 대기압 오프셋을 동적 보정하기 위해 사용됩니다.
온-보드 공압계 |
|
예열시간 | 필요 없음 |
범위 | 70 ~ 110 kPa (10 ~ 16 psi) |
분해능 | 스팬의 0.001% |
정밀도 예측 안정도 |
스팬의 0.1% 0.05 kPa/yr (0.008 psi/yr) |
압력 제어기 사양 |
|
조절 정밀도 | PPC4E: 제어기 스팬의 ±0.0006% PPC4EX: |
제어 가능한 최저 압력 (계기 모드) |
자동 배기를 통한 영점 조절 영점 상하의 최저점으로 RPT 해상도와 제어 정밀도의 영향을 받음 |
제어 가능한 최저 압력 (절대모드, 네거티브 모드 계기 모드) |
PPCC4E 7M과 PPC4E 14M을 제외한 모든 모델에서 1 kPa 절대 (0.15 psia)혹은 계기 동등값
PPC4E 7M의 경우 3.5 kPa (0.5 psia) PPC4E 7M의 경우 7 kPa (1 psia) |
최대 압력 (절대, 네거티브 계기) 진공 펌프와 커넥터에 따라 다름 |
200 ~ 700 Pa (2 to 7 mbar, 0.03 to 0.1 psia) 절대 혹은 계기 동등값 |
평균 압력 설정 준비 시간 (0.005% 홀드 한계, 50 cc 테스트 용적) |
15~30초 |
슬루(Slew) 시간 (50 cc 테스트 부피로 ATM 에서 FS까지) |
30 s |
일반 테스트 부피 | 1.4 MPA의 제어기 범위의 경우 0 ~ 1000 cc [300 psi] 이하 1.4 MPA [300 psi] 이상의 제어기 범위의 경우 0 ~ 500 cc |
기본 동적 제어 홀드 한계 | ±0.01% of current range |
Model Name | 설명 |
---|---|
PPC4E 15K |
PPC4E 제어기/교정기 |
6241-15K |
PPC4E 가스 압력 컨트롤러 키트 - PPC4E 15K, ±1.5~±15kPa(±0.2~±2.2psi) 구성 요소:
|
6241-100K |
PPC4E 가스 압력 컨트롤러 키트 - PPC4E 100K, ±10~±100kPa(±1.5~±15psi) 구성 요소:
|
6241-1.4M |
PPC4E 가스 압력 컨트롤러 키트 - PPC4E 1.4M, 140~1,400kPa(20~200psi) 구성 요소:
|
6241-7M |
PPC4E 가스 압력 컨트롤러 키트 - PPC4E 7M, 700~7,000kPa(100~1,000psi) 구성 요소:
|
6242-100K |
PPC4E 가스 압력 컨트롤러 키트 - PPC4EX 100K, ±1~±100kPa(±0.15~±15psi) 구성 요소:
|
6242-1.4M |
PPC4E 가스 압력 컨트롤러 키트 - PPC4EX 1.4M, 14~1,400kPa(2~200psi) 구성 요소:
|
6242-7M |
PPC4E 가스 압력 컨트롤러 키트 - PPC4EX 7M, 70~7,000kPa(10~1,000psi) 구성 요소:
|
6242-14M |
PPC4E 가스 압력 컨트롤러 키트 - PPC4EX 14M, 140~14,000kPa(20~2,000psi) 구성 요소:
|
Accessories common to all models:
액세서리 | 설명 |
---|---|
PK-PPC-BG-DVU |
BG15K Q-RPT 와의 사용을 위한 2용량 유닛 |
랙설치키트 |
랙설치키트 19인치랙을 위한 랙설치키트 |
RPM4 |
외부 Q-RPT 그리고/또는 절대모드 AutoZ 를 위한 기준압력 모니터 |
RS232 |
PPC4E COM1 을 위한 9핀,2m |
기준 진공키트, 220 V |
PPC EXHAUST 포트를 위한 진공펌프 패키지 연결 포함 |
기준 진공키트, 110 V |
PPC EXHAUST 포트를 위한 진공펌프 패키지 연결 포함 |
압력을 위한 COMPASS |
자동화 , 데이터 수집,보고와 자산관리의 자동화를 위한 소프트웨어 |
Priority Gold Instrument CarePlan |
Fluke Calibration Priority Gold Instrument CarePlan은 대부분의 교정 제품에 제공됩니다. 자세한 내용을 확인하거나 견적을 요청하려면 지역 Fluke Calibration 판매 담당자에게 문의하십시오. 877-355-3225로 고객 관리 센터에 전화하거나 careplans@flukecal.com으로 이메일을 보내실 수도 있습니다. |
Silver CarePlan |
Fluke Calibration Silver CarePlan은 대부분의 교정 제품에 제공됩니다. 자세한 내용을 확인하거나 견적을 요청하려면 지역 Fluke Calibration 판매 담당자에게 문의하십시오. 877-355-3225로 고객 관리 센터에 전화하거나 careplans@flukecal.com으로 이메일을 보내실 수도 있습니다. |
- Home
- Products
- New Products
- Electrical Calibration
- RF Calibration
- Data Acquisition and Test Equipment
- Temperature Calibration
- Humidity Calibration
- Pressure Calibration
- Flow Calibration
- Process Calibration Tools
- Calibration Software
- Service and Support
- All Calibration Instruments
- Handheld Test Tools
- Purchase Info
- News
- Training and Events
- Literature and Education
- Service and Support
- Service Request (RMA)
- Service Plans
- Technical Support
- Knowledge Base
- Accreditations
- Authorized Service Centers
- Calibration Certificates
- Community Forum
- My MET/SUPPORT
- Product Manuals (User Guides)
- Safety Data Sheets (SDS)
- Recycle Program
- Safety, Service, and Product Notices
- Software Downloads
- Warranties
- Tools
- About Us
Sidebar Request a Quote
견적 요청