Expand the workload capability of your power and electrical calibrators
52120A performance at a glance
- Industry-leading amplifier accuracy:
- - 140 ppm ac (used with 61XXA Electrical Power Standard or 5730A)
- - 350 ppm ac (used with dc/lf calibrator
- - 160 ppm dc (used with dc/lf calibrator
- Frequency: DC to 10 kHz
- Burden voltage (compliance): 4.5 V @ 120 A
- Inductive drive capability: 1 mH load
- Output ranges: 2 A, 20 A, 120 A
- Input ranges: 2 V or 200 mA F.S. for 2 A and 20 A ranges, 1.2 V or 120 mA F.S. for 120 A range
- Parallel operation: (Closed loop mode with 61XXX or 5730A) 2 or 3 amplifiers, up to 360 A in a single phase
- Parallel operation: (Standalone mode), up to 10 amplifiers, up to 1200 A in a single phase
- Accessory coils: 25-turn coil supports 3000 A, 50-turn coil supports 6000 A
- Control communication with 6105A/6100B Electrical Power Standards or 5730A
- GPIB remote operation
- Calibration professionals in a calibration/standards lab or an electrical utility
- Manufacturers of power/energy instrumentation and meters, power quality analyzers or power converters
- Users of electrical test and measurement equipment
The 52120A operates as a transconductance amplifier with:
- 5522A/5502A/5520A/5500A Multi-Product Calibrators
- 5730A*/5700A/5720A Multifunction Calibrator
- 6105A*/6100B* Electrical Power Standard
- 5080A Multi-Product Calibrator
- 9100 Universal Calibration System
- Any calibrator, signal generator or power supply capable of sourcing 2 V or 200 mA, dc or ac
You may also operate your 52120A in closed-loop mode, seamlessly communicating with your Fluke Calibration 6105A or 6100B Electrical Power Standard to deliver enhanced 52120A accuracy.
Operating limits | |
Output ranges | 2 A, 20 A, 120 A (100 A dc) |
Input current range | 200 mA, 200 mA, 120 mA (100 mA dc) |
Current gain | 10, 100, 1000 |
Input voltage range | 2 V, 2 V, 1.2 V (1.0 V dc) |
Transconductance | 1,10,100 Siemens |
Frequency | To 10 kHz |
Maximum output compliance voltage | 4.5 Vrms (6.4 Vpeak) |
Inductive drive capability: | 1 mH load |
Output isolation, current terminal to earth | 600 Vrms, 850 Vpeak, dc to 850 Hz |
Performance specifications | |
AC accuracy, closed loop with 6105A | To 140 ppm |
DC accuracy, standalone | To 160 ppm |
AC accuracy, standalone | To 350 ppm |
Phase angle accuracy | 0.006° |
Load dependent phase angle shift | <0.001° @ 60 Hz |
General specifications | |
Input line voltage range | 100 V to 240 V with up to ±10 % fluctuations |
Transient overvoltage | Impulse withstand (overvoltage); Category II of IEC 60364-4-443 |
Frequency | 47 Hz to 63 Hz |
Maximum consumption | < 1500 VA |
Calibration Documentation | Report of calibration with data included; 17025 accredited report optional |
Dimensions with feet (H x W x L) | 192 mm x 432 mm x 645 mm (7.6 inches x 17 inches x 25.5 inches) |
Dimensions without feet (H x W x L) | 178 mm x 432 mm x 645 mm (7 inches x 17 inches x 25.5 inches) |
Weight | 25 kg (54 lb.) |
Design standards and compliance | Designed to EN 61010-1: 2010, CAN/CSA 22.2 No 61010.1-04, ANSI/UL 61010-1:2004, EN 61326-1:2006 CE marked, CSA listed |
Operating temperature | 5 °C to 35 °C |
Calibration temperature range | 16 °C to 30 °C |
Warm up time | 1 hour |
Safe operating max. relative humidity (non-condensing) | <80 % 5 °C to 31 °C ramping linearly down to 50 % at 35 °C |
Operating altitude | 0 m to 2,500 m |
Shock and vibration | MIL-PRF-28800F class 3 |
Specification confidence level | 99% |
Model Name | Description |
---|---|
52120A |
Transconductance Amplifier |
Accessories common to all models:
Accessory | Description |
---|---|
52120A/COIL3KA |
Coil, 25 Turn, 3000 Amp |
52120A/COIL6KA |
Coil, 50 Turn, 6000 Amp |
52120A/COIL12V |
Coil 12 V DC Supply |
Application Notes |
---|
![]() |
![]() |
Firmware |
---|
52120A Transconductance Amplifier Firmware Upgrade |
Specifications |
---|
![]() |
- Home
- Products
- New Products
- Electrical Calibration
- RF Calibration
- Data Acquisition and Test Equipment
- Temperature Calibration
- Humidity Calibration
- Pressure Calibration
- Flow Calibration
- Process Calibration Tools
- Calibration Software
- Service and Support
- All Calibration Instruments
- Handheld Test Tools
- Purchase Info
- News
- Training and Events
- Literature and Education
- Service and Support
- Service Request (RMA)
- Service Plans
- Technical Support
- Knowledge Base
- Accreditations
- Authorized Service Centers
- Calibration Certificates
- Community Forum
- My MET/SUPPORT
- Product Manuals (User Guides)
- Register Products
- Safety Data Sheets (SDS)
- Recycle Program
- Safety, Service, and Product Notices
- Software Downloads
- Warranties
- Tools
- About Us
Sidebar Request a Quote
Request a quote

We'd like your feedback.
You can help us improve our website »
Thank you!
If you purchased an item from a Fluke authorized distributor, please contact them directly with questions regarding Certificates of Calibration or other documentation.
Support requests for items purchased from, or serviced directly by Fluke and general Metrology questions can be submitted via our online Support Request form and a Fluke representative will be in contact with you.