A40B Series Precision DC and AC Current Shunts

A40B Series Precision DC and AC Current Shunts
AC current shunts electrical
AC current shunts electrical
AC current shunts electrical
A40B Series Precision DC and AC Current Shunts
AC current shunts electrical
AC current shunts electrical
AC current shunts electrical
Request a quote
  • Highlights
  • Description
  • Specifications
  • Models and Accessories
  • Knowledge and Information

Precision, low inductance shunts for dc and ac current metrology

The A40B dc and ac precision current shunt set consists of 14 low-inductance coaxial current shunts, adapters and connectors, and a rugged transit/storage case. Designed for currents from 1 mA to 100A, the current shunts are for laboratory use in making directly measured absolute ac or dc current measurements as well as ac/dc current transfer measurements. They exhibit outstanding resistance value stability, with an excellent self-heating power coefficient, and a low temperature coefficient. With all of these characteristics combined, the shunts offer direct measurement of current from dc to 100 kHz with higher accuracy than previous commercially available shunt technology. Now precision measurements can be made in a single step process rather than by more complex traditional ac/dc transfer methods.

  • Simplifies calibration/verification of precision calibrators and current sources
  • Shunts sized for currents from 1mA to 100A
  • Usable from dc to 100 kHz
  • 14 individual dc and ac current shunts with a 1, 2, 5 sequence over 6 decades of current
  • Simple direct measurements, making ac/dc transfers unnecessary
  • Stability typically better then ± 5.0 µΩ/Ω for one year
  • Typical angular accuracy of better than ± 0.003º at 1 kHz

Application

The wide range of shunt values permit measuring from 0.1 mA to 100 Amps. The physical construction and the components used in the current shunts ensure that the frequency response is very flat (amplitude displacement error relative to dc resistance). Also the phase displacement at 100 kHz is small enough to be neglected in all but the highest accuracy measurements. Combined with excellent dc resistance stability, the shunts can be used to directly measure current through their full bandwidth. This simplifies precision ac current measurements as the complex ac/dc transfer measurement process will no longer be necessary for many precision current measurement applications. These characteristics make the A40B shunts ideal for traditional precision current applications such as calibrator verification. Also, the wide current range allows verification of high current transconductance amplifiers. The low phase shift error is critical for measurement of non-sinusoidal wave shapes, as found in power quality or sampling digital wattmeter measurement applications.

Technical overview

The shunts come in four different sizes. The full current shunt set includes:

  • four fully enclosed dc and ac current shunts: 1 mA, 10 mA, 20 mA, 50 mA
  • five small size radial dc and ac current shunts: 100 mA, 200 mA, 500 mA, 1 A, 2 A
  • three medium size radial dc and ac current shunts: 5A, 10 A, 20 A
  • two large size radial dc and ac current shunts: 50 A, 100 A

Voltage output is nominally 0.8 volts for the nominal rated current input. The output is measured by a voltmeter or detector, such as precision voltmeters, ac measurement standards, ac/dc transfer standards, or thermal voltage converters, fitting them to a wide variety of metrology applications.

The radial style dc and ac current shunt design gives high performance with minimum external magnetic fields. Plus, the open nature of the dc and ac current shunt physical design maximizes air flow so the shunts have a minimal power coefficient effects. This permits each shunt to be used over a wide range of currents with stable resistance characteristics.

The dc and ac current shunt resistance is designed to minimize interaction with the detector instrumentation. The 100 Amp shunt resistance is 8 milliohms, with shunt resistance increasing to 80 ohms for the 10 mA shunt. Additionally, the 1mA shunt includes an internal battery operated buffer amplifier. It drives the output voltage so the 800 ohm shunt resistance has minimal interaction with the measurement device.

Reports of calibration

The A40B series of precision DC and AC Current Shunts come with an ISO 17025 Accredited Certificate of Calibration.

Basic Electrical Specification Summary

Shunt
Nominal
Current
Nominal
Resistance
(Ohms)
Basic Specification ±μA/A, TCal ±1 °C, ≤50 % RH
DC 1 kHz 10 kHz 30 kHz 100 kHz
1 mA 800 20 55 75 75 150
10 mA 80 20 26 26 26 26
20 mA 40 20 26 26 26 26
50 mA 16 20 23 23 23 23
100 mA 8 20 24 24 24 24
200 mA 4 20 26 26 26 26
500 mA 1.6 21 27 27 27 28
1 A 0.8 21 27 28 28 31

2 A

0.4 21 27 30 30 48
5 A 0.16 21 31 32 40 71
10 A 0.08 26 37 60 61 92
20 A 0.04 26 43 52 70 113
50 A 0.016 32 55 80 81 144
100 A 0.008 35 65 90 98 174

Maximum AC-DC Difference

Shunt Nominal Current: Maximum AC-DC Difference (± ppm)1,2
  1 kHz 100 kHz
1 mA3 53 150
10 mA 20 40
20 mA 18 30
50 mA 13 16
100 mA 14 27
200 mA 17 28
500 mA 17 21
1 A 17 23
2 A 17 44
5 A 23 69
10 A 28 98
20 A 37 150
50 A 47 180
100 A 60 300
1 Specifications indicate the maximum flatness deviation from dc, and include both measured AC-DC difference and the uncertainty of measurement. They are stated at k=2, approximately 95 % confidence.
2 Includes 1-year stability of the AC-DC difference.
3 Specifications for the 1 mA current shunt are for TCal ± 1 °C.
General Specifications
Calibration Documentation 17025 accredited report of calibration included
Dimensions (maximum)
Shunt Value:  1 mA to 2 A
Height:  70 mm (2.75 in)
Width:  70 mm (2.75 in)
Overall Length1:  
124 mm (4.9 in)
Shunt Value:  5 A to 20 A
Height:  130 mm (5 in)
Width:  130 mm (5 in)
Overall Length1:  
210 mm (8.25 in))
Shunt Value:  50 A and 100 A
Height:  200 mm (7.9 in)
Width:  200 mm (7.9 in)
Overall Length1:  343 mm (13.5 in))
1 Includes input and output connectors; subject to change by component vendor.
Physical/mechanical parameters
Shunt Value:  1 mA to 20 A
Weight:  0.7 kg (1.6 lb)
Input Connector:  Type-N (female)
Output Connector:  Type-N (female)
Shunt Value:  50 A and 100 A
Weight:  3.4 kg (7.5 lb)
Input Connector:  Type-LC (female)
Output Connector:  Type-N (female)
Operating environment
Temperature: 13 °C to 33 °C
Calibration temperature (TCal) range: 18 °C to 28 °C
Humidity range for best specification 1,2: ≤ 50 % RH
Altitude: 0 m to 3,000 m
1 Resistance stability is affected by humidity, but changes are reversible.
2 If the shunts are calibrated outside this RH, stability specifications will be met as long as the shunts are stored and used at the same relative humidity ± 10 % RH.
Storage and transit environments (for models other than the 1 mA current shunt)
Temperature to avoid damage: -20 °C to 140 °C
Temperature and humidity to maintain performance1: 5 °C to 45 °C; 15 % to 80 % RH
Non-operating altitude: 0 m to 12,000 m
1 Storage at extremes of temperature or humidity will cause a temporary change of shunt resistance by up to ± 20 ppm. When subsequently stored or used within the limits of the operating environment, the shunts will recover to their original resistance value within 30 days.
Additional 1 mA current shunt specifications
Output resistance 8 mΩ
Maximum safe output current 11 mA (e.g., 1 V output into 90 Ω)
Maximum capacitive load 800 pF
Output voltage regulation 15 ppm/100 pF
Maximum output dc v offset ± 100 μV (typical ± 25 μV)
Typical error @ 1 MHz < 2 %
Battery specifications
Battery size AAA (44.5 mm x 10.5 mm)
Battery technology Nickel-Metal Hydride (NiMH)
Number of batteries required 8 (in 2 groups of 4)
Nominal battery voltage 1.2 V (4.8 V per group of 4)
Typical battery capacity 800 mAh
Storage and transit environment to preserve the batteries
Less than 90 days:  -20 °C to 40 °C
Less than one year:  -20 °C to 30 °C
Charging time (from fully discharged):  100 minutes
Maximum operating time between charges
Maximum output load (11 mA):  18 hours
High impedance load:  24 hours
Recommended cooling period:  100 minutes
  To prevent loss of battery capacity recharge at least twice per year.

Model Name Description
A40B/SET

Complete set of shunts including:

  • 14 shunts
  • transit case
  • A40B-ADAPT/LC LC Male to LC Male adapter (1)
  • A40B-ADAPT/LCN LC Female to N Male inter-series adapter (1)
  • A40B-LEAD/4MM N to 4 MM double banana connector (2)
  • A40B-LEAD/N N Male to N Male lead (1)

A40B-001MA

1 milliamp Current Shunt

A40B-010MA

10 milliamp Current Shunt

A40B-020MA

20 milliamp Current Shunt

A40B-050MA

50 milliamp Current Shunt

A40B-100mA

100 milliamp Current Shunt

A40B-200mA

200 milliamp Current Shunt

A40B-500mA

500 milliamp Current Shunt

A40B-1A

1 amp Current Shunt

A40B-2A

2 amp Current Shunt

A40B-5A

5 amp Current Shunt

A40B-10A

10 amp Current Shunt

A40B-20A

20 amp Current Shunt

A40B-50A

50 amp Current Shunt

A40B-100A

100 amp Current Shunt

Accessories common to all models:

Accessory Description
A40B-ADAPT/LC

LC Male to LC Male adapter

A40B-ADAPT/LCN

Female to N Male inter-series adapter

A40B-CAL/LC

High current adapter to connect two shunts in series for measurement (LC to LC)

A40B-CAL/N

Low current adapter to connect two shunts in series for measurement (N to N)

A40B-CASE

Fiberglass Transit Case

A40B-LEAD/4MM

N to 4 mm double banana connector

A40B-LEAD/N

N Male to N Male lead

A40B-ADAPT/SPADE

 LC male to spade lug terminals

Product Manuals
application/pdf icon A40B Instruction Manual (English) (854.4 KB)
application/pdf icon A40B Instruction Manual Supplement (21.92 KB)
application/pdf icon A40B Instruction Manual (Rus) (1.27 MB)
application/pdf icon A40B Statement of Memory Volatility (16.45 KB)
Application Notes
application/pdf icon Calibrating current sources using A40B Series Current Shunts and the 5790B AC Measurement Standard (2.34 MB)
Data Sheets
application/pdf icon A40B Precision Current Shunts Adapters, Cables and Connectors (789.83 KB)
application/pdf icon A40B Series Precision Current Shunts Data Sheet (795.94 KB)
application/pdf icon 电流测量的新突破-A40B精密分流器 (517.35 KB)
FAQs
application/pdf icon A40B Precision Current Shunts: Answers to Frequently Asked Questions (1.49 MB)
Papers / Articles
application/pdf icon Calibrating Precision Multimeters Using a Characterized Multifunction Calibrator (268.09 KB)
application/pdf icon 使用多功能校准器特性修正技术校准高精度数字多用表 (1.4 MB)
Video
Fluke 5790B Measurement Standard Demo Video
White Paper
application/pdf icon Characterization of the Power Coefficient of AC and DC Current Shunts (748.55 KB)
  • Printer-friendly version »
  • Home
  • Products
    • New Products
    • Electrical Calibration
      • Electrical Standards
      • Electrical Calibrators
      • Bench Multimeters
      • Electrical Calibration Software
    • RF Calibration
      • RF Reference Sources
      • RF Calibration Accessories
      • RF Calibration Software
    • Data Acquisition and Test Equipment
      • Bench Multimeters
      • Data Acquisition
      • Data Acquisition Software
    • Temperature Calibration
      • ITS-90 Temperature Standards
        • ITS-90 Fixed-point cells
        • Standard Platinum Resistance Thermometers
        • Maintenance Apparatus
        • Liquid Nitrogen Comparison Calibrator
        • Resistance Bridges
        • Standard Resistors
      • Calibration Baths
        • Compact Calibration Baths
        • Standard Calibration Baths
        • Special Application Baths
        • Bath Accessories
        • Bath Controllers
        • Bath Fluids
      • Industrial Calibrators
        • Field Metrology Wells
        • Metrology Wells
        • Handheld Calibrators
        • Field Dry-Block Calibrators
        • Micro Baths
        • Infrared Calibrators
        • Thermocouple Furnaces
        • Dual Block Dry-Well
        • Zero-point Dry-Well
      • Probes / Sensors
        • Platinum Resistance Thermometers (PRTs)
        • Thermistors
        • Thermocouples
      • Digital Thermometer Readouts
      • Multifunction Calibrators
      • Temperature Calibration Software
    • Humidity Calibration
      • Humidity Generators
      • Humidity Data Loggers and Monitors
    • Pressure Calibration
      • Piston Gauges
        • NMI Piston Gauges
        • Absolute Piston Gauges
        • High Pressure Pneumatic Piston Gauges
        • Hydraulic Piston Gauges
        • Piston Gauge Accessories
      • Automated Pressure Controller / Calibrators
        • Low Pressure Controllers / Calibrators
        • Pneumatic Pressure Controllers / Calibrators
        • High Pressure Pneumatic Controller / Calibrators
        • Hydraulic Controller / Calibrators
      • Pressure Monitors
        • Low Pressure Monitors
        • Digital Pressure Gauges
        • Reference Pressure Monitors
      • Deadweight Testers
        • Pneumatic Deadweight Testers
        • Oil Deadweight Testers
        • Water Deadweight Testers
        • High-Pressure Hydraulic Deadweight Testers
        • Deadweight Tester Accessories
      • Manual Pressure Calibration
        • Pressure Calibrators
        • Pneumatic Pressure Control
        • Hydraulic Pressure Comparators / Pumps
      • Handheld Pressure Calibrators
      • Air Data Calibration
      • Environmental Monitors
      • Pressure Calibration Accessories
      • Pressure Calibration Custom Systems
      • Pressure Calibration Software
    • Flow Calibration
      • Gas Flow Standards
      • Gas Flow Accessories
      • GFS Primary Gravimetric Flow Standard
      • Flow Calibration Software
    • Process Calibration Tools
      • Temperature Calibrators
        • Handheld Temperature Calibrators
        • Dry-Block Calibrators and Micro-Baths
        • Precision Digital Thermometers
        • Temperature Probes
        • Infrared Calibrators
        • Hygro Thermometer with Data Logging
      • Pressure Calibrators
        • Digital Pressure Calibrators
        • Handheld Pressure Calibrators
        • Deadweight Testers
        • Precision Digital Pressure Gauges
        • Calibration Hand Pumps
      • Multifunction Calibrators
      • mA Loop Calibrators
      • Process Calibration Software
    • Calibration Software
      • MET/CAL® Software
      • MET/CAL® Support
      • Asset Management Software
      • Temperature Calibration Software
      • Pressure Calibration Software
      • Flow Calibration Software
      • Mechanical / Dimensional Calibration Software
    • Service and Support
    • All Calibration Instruments
    • Handheld Test Tools
  • Purchase Info
    • Where to Buy
    • Request a Quote
    • Request a Demo
    • Request a Sales Consultation
    • Certified Pre-Owned Equipment
    • General Services Administration (GSA)
    • Financing Program
    • National Stock Numbers (NSNs)
    • Payment Options and Tax Info
  • News
    • Press Releases
    • Promotions
    • Industry Links
    • Metrology Salary Survey
  • Training and Events
    • Conferences and Exhibitions
    • Training Courses
    • User Group Meetings
    • Web Seminars
      • Live Seminars
      • On-Demand Seminars
  • Literature and Education
    • Education Hub
    • About Calibration
    • Articles and Education
    • Product Literature
    • Product Manuals (User Guides)
    • Videos and Virtual Demos
    • Resource Centers
    • Blog
  • Service and Support
    • Service Request (RMA)
    • Service Plans
    • Technical Support
    • Knowledge Base
    • Accreditations
    • Authorized Service Centers
    • Calibration Certificates
    • Community Forum
    • My MET/SUPPORT
      • Activate
      • Procedures
      • Software
      • Technical Bulletins
      • Priority Support
      • Manuals
    • Product Manuals (User Guides)
    • Safety Data Sheets (SDS)
    • Recycle Program
    • Safety, Service, and Product Notices
    • Software Downloads
    • Warranties
    • Tools
      • PT100 Calculator
      • ITS-90 Reference Function Calculator
      • Thermocouple Table Voltage Calculator
      • Thermocouple Voltage to Temperature Calculator
  • About Us
    • Contact Us
    • Visit Us
    • Employment
    • Fluke Calibration
      • Hart Scientific Temperature Calibration
      • DH Instruments Pressure and Flow Calibration
      • Pressurements Pressure Calibration
      • Ruska Pressure Calibration
    • Fluke Companies
    • Integrity and Compliance
    • Frequently Asked Questions
    • Why buy Fluke Calibration ?
Home|Products|Electrical Calibration|Electrical Standards|A40B Series Precision DC and AC Current Shunts

Sidebar Request a Quote

Request a quote

Your information is protected by our privacy policy.

©1995-2023 Fluke Corporation
             

Secondary menu

  • Disclaimer
  • Privacy Statement
  • Terms of Use
  • Terms of Sale