- Other Fluke companies:
- Fluke
- Fluke Biomedical
- Fluke Networks
- Fluke Process Instruments
- Dual range, select from 10/30 inH2O or 20/60 inH2O or 35/100 inH20 range combinations
- Precision: 0.005 % of reading from 10 % to 100 % Full Scale (FS)
- Control stability: 0.004 % of each range
- Resolution to 0.0001 inH2O
- Time to set point: 30 seconds with no overshoot
- Languages: English, French, Chinese, German, Japanese, Spanish and Italian
The 7250LP low pressure digital pressure calibrator, part of the versatile Series 7250 family, is specifically designed to meet the demanding performance requirements of calibrating low pressure sensors, transducers, mechanical gauges, portable calibrators and their plug-in modules. To accommodate bidirectional devices, the 7250LP can be supplied to operate in both positive and negative gauge modes. The 7250LP offers unmatched performance and enhanced control stability.
Utilizing multiple ranges in a single instrument, the 7250LP combines precision, stability, speed and affordability. The 7250LP has a unique quartz sensor, the most accurate pressure sensing technology available in a digital pressure calibrator. Each quartz sensor is manufactured and tested to provide the ultimate performance required by a Fluke Calibration pressure calibrator, ensuring that every customer receives the highest quality, precision and stability in their instrument.
- Vacuum (negative gauge) mode for bidirectional devices
- Rack mount kit
- COMPASS® for Pressure software
- MET/CAL® software driver
The 7250LP low pressure digital pressure calibrator can easily automate low pressure test and calibration workload. The 7250LP is easy to use, easy to maintain and has the reliability, performance, and features you want.
Pressure Ranges |
|
Model 7250LP | Select from three range combinations: 10 in H2O and 30 in H2O or 20 in H2O and 60 in H2O or 35 in H2O and 100 in H2O |
Optional Modes | Vacuum (negative gauge) Other Series 7250 digital pressure controllers are available in a variety of ranges from 5 to 3000 psig (350 mbar to 207 bar). |
Performance |
|
Precision | 0.005% of reading from 10% FS to 100% FS. Fixed error of 0.005% of 10% FS from 0% to 10% FS
Precision is defined as the combined effects of linearity, repeatability and hysteresis throughout the operating temperature range. Expression of accuracy (uncertainty) conforms with the recommendations of the ISO guide to the expression of uncertainty in measurement. |
Stability | 0.0075% of reading, per year |
Control Stability | Active mode: 0.004% of each range Passive mode: no additional uncertainty |
Display Resolution | User selectable to 1:1,000,000 |
Control Response | Optimized for 5 in3 load volume (included with 7250LP) Maximum 30 in3 load volume |
Negative Gauge Precision (optional) | 7250LP: 0.005% of reading from 10% to 100% of FS |
Total Uncertainty |
|
Maximum deviation from the true value of pressure including precision, stability, temperature effects and the calibration standard | 10 in H2O range/30 in H2O range 0.009% of reading or 0.00015 in H2O 20 in H2O range/60 in H2O range 35 in H2O range/100 in H2O range |
General |
|
Display | TFT, VGA, active matrix, 6.4 in (163 mm) 640 x 480 resolution, 65,000 colors |
Temperature | Operating: 64°F to 97°F (18°C to 36°C) Storage: -4°F to 158°F (-20°C to 70°C) |
Humidity | 5% to 95% relative humidity, non-condensing |
Dimensions | (h x w x d) All versions: 7 in x 16.5 in x 19 in (178 mm x 419 mm x 483 mm) |
Weight | Model 7250/7250i: 17 lb (7.7 kg) Model 7250xi: 20 lb (9 kg) |
Test Port and Supply Connection | 1/4 in NPT female |
Warm Up Time | 2 to 3 hours; may be left on indefinitely |
Pressure Medium | Nitrogen or clean dry air |
Model Name | Description |
---|---|
7250LP |
Low Pressure Digital Pressure Calibrator |
Accessories common to all models:
Accessory | Description |
---|---|
Priority Gold Instrument CarePlan |
Fluke Calibration Priority Gold Instrument CarePlans are available for most calibration products. Please contact your local Fluke Calibration sales representative for details or to request a quote. You may also call the Customer Care Center at 800-882-6153 or send email to premiumcare@fluke.com. |
Silver CarePlan |
Fluke Calibration Silver CarePlans are available for most calibration products. Please contact your local Fluke Calibration sales representative for details or to request a quote. You may also call the Customer Care Center at 877-355-3225 or send email to careplans@flukecal.com. |
7000-102 Liquid Trap |
Liquid trap assembly |
Product Manuals |
---|
Application Notes |
---|
Data Sheets |
---|
Software |
---|
7250 Series Pressure Controllers - Main Firmware Version 1R60 |
Papers / Articles |
---|
On-Demand Webinars |
---|
Pressure Series, Part 2 of 3 - Intermediate Pressure Calibration |
- Home
- Products
- New Products
- Electrical Calibration
- RF Calibration
- Data Acquisition and Test Equipment
- Temperature Calibration
- Humidity Calibration
- Pressure Calibration
- Flow Calibration
- Process Calibration Tools
- Calibration Software
- Service and Support
- All Calibration Instruments
- Handheld Test Tools
- Purchase Info
- News
- Training and Events
- Literature and Education
- Service and Support
- Service Request (RMA)
- Service Plans
- Technical Support
- Knowledge Base
- Accreditations
- Authorized Service Centers
- Calibration Certificates
- Community Forum
- My MET/SUPPORT
- Product Manuals (User Guides)
- Safety Data Sheets (SDS)
- Recycle Program
- Safety, Service, and Product Notices
- Software Downloads
- Warranties
- Tools
- About Us
Sidebar Request a Quote
Request a quote