• Other Fluke companies:
  • Fluke
  • Fluke Biomedical
  • Fluke Networks
  • Fluke Process Instruments
See more Fluke brands
Accelix Amprobe Beha-Amprobe Comark Emaint Landauer Pacific Laser Systems Pomona RaySafe Schad
Home
Precision, Performance, Confidence.
Fluke Calibration: Europe
  • Register
  • Log in
  • Contact Us

EU - English [Change]

 

Get Quote

96040A Low Phase Noise Reference Source

96040A Low Phase Noise Reference Source
96040A Low Phase Noise Reference Source
96040A Low Phase Noise Reference Source
96040A Low Phase Noise Reference Source
96040A Low Phase Noise Reference Source
96040A Low Phase Noise Reference Source
96040A Low Phase Noise Reference Source
96040A Low Phase Noise Reference Source
Request a quote
  • Highlights
  • Description
  • Specifications
  • Models and Accessories
  • Knowledge and Information

 Simplify your RF calibration system

The Fluke Calibration 96040A RF Reference Source enables you to simplify your RF calibration system by replacing many of the instruments and accessories that make up your current system. Its precision signal level and attenuation, high signal purity and precision low distortion modulation make this reference source superior to the general-purpose signal generators that are often used to calibrate spectrum analyzers, modulation meters, RF sensors, attenuators, and similar instruments. Its low phase noise provides superior phase noise performance.

Unlike many RF calibration solutions, the 96040A is designed specifically for RF calibration, with a calibration-oriented user interface that makes it easy to learn and use. The 96040A speeds up calibration procedures, reduces opportunities for operator errors, and greatly simplifies RF metrology. As the core of an RF and microwave calibration system, the 96040A covers the majority of test points required for calibrating spectrum analyzers of any frequency range.

Automated with MET/CAL® Plus Calibration Management Software, the 96040A reduces complexity and calibration times, dramatically improving efficiency and increasing capacity by 50 % or more over manual methods.

Key benefits

  • Covers a broad range of RF calibration workload
  • Reduces the number of instruments and interconnections required for your RF calibration system
  • “What you set is what you get” accurate signal delivery direct to the DUT input
  • Integrated 50 MHz frequency counter eliminates need for an additional instrument • Calibration-specific interface simplifies technician tasks
  • Simplifies uncertainty calculations by delivering known signals direct to the device under test (DUT)
  • Lowers RF system maintenance costs
  • With automation, reduces spectrum analyzer calibration times by as much as 50% over manual methods

Broad, versatile workload coverage

The 96040A calibrates a broad workload of RF calibration devices, including:

• Spectrum analyzers

• Modulation meters and analyzers

• RF power meters and sensors

• Frequency counters

• Attenuators

• And more

The metrology associated with calibrating these items becomes simpler because you have fewer error sources and uncertainty contributions to consider.

More than just an RF calibrator

There are many applications in research and development, manufacturing test, and ATE needing better performance than a general purpose signal generator. If wide frequency coverage, frequency resolution, low harmonics, phase noise and spurious content, signal level and attenuation accuracy, or dynamic range are critical parameters the 96040A is an ideal solution.

Cut the cost of your RF calibration system in half

As the central instrument in a high capability RF spectrum analyzer calibration system, the 96040A can cut your costs in half. The 96040A replaces all of these parts of a “typical” RF calibration system:

Up to four signal sources (from audio/ function generators to RF signal and low phase noise sources)

  • Power meters and power sensors
  • Step attenuators
  • Filters
  • Pads
  • Couplers
  • 50 MHz frequency counter

The 96040A not only reduces the initial need to purchase, install and configure RF system components, but it also reduces the maintenance and calibration costs associated with all of that equipment. The 96040A is also easier to transport than a heavy rack of equipment and accessories, making it a good solution for on-site calibration.

With its 4 GHz frequency range, the 96040A performs more than 80 % of all the tests required on high performance, high frequency spectrum analyzers.

For workload items that require frequencies beyond 4 GHz, you can use an RF and microwave source that you probably already own alongside the 96040A to address the few remaining higher frequency test points. For many spectrum analyzer models operating below 4 GHz, you only need a 96040A to perform the entire calibration. You can’t simplify much more than that!

No need for additional function generators

The 9640A Reference Source’s internal modulation capability makes it suitable for applications that require precision modulation to be applied to the output signal, such as modulation analyzer calibration and spectrum analyzer sweep time testing using an AM signal with more accurate modulation rates. You don’t need additional function generators as a low frequency modulation source—the 96040A delivers it all.

Designed for RF calibration

The 96040A user interface is designed to simplify processes for calibrating typical items in your workload, such as spectrum analyzers, RF level meters and receivers. Parameter offset, stepping, relative and DUT error readout modes allow you to work accurately and efficiently, following familiar calibration procedures. You’ll find it easier than ever to determine the performance and tolerances of units under test.

The 96040A front panel is equipped with dedicated function keys, context-sensitive softkeys, and a bright, easy-to-read color display that make it easy to learn and operate. You can set output levels in terms of power (watts or dBm), voltage (RMS or peak to peak) using familiar multipliers and exponent forms. You can move easily between voltage, power and dBm units without losing entered values or accuracy. In error readout mode to adjust the reading, simply rotate the spin wheel and the DUT error is displayed directly in dB, ppm or percent.

The simple, calibration-oriented user interface also makes troubleshooting easier if you encounter an unexpected result or an out-of-tolerance condition while following a manual or automated calibration procedure.

“What you set is what you get” accuracy and signal purity

A rugged, precise levelling head delivers 96040A signal levels directly to the device under test (DUT) input just the way you set them on the front panel. This unique “What you set is what you get” feature helps you avoid problems like losses, noise, interference, and mismatch errors, which can be caused by using intermediate connectors and cables. This approach also maintains the integrity of low-level signals. The head maintains signal precision and noise immunity throughout a 154 dB dynamic range, down to the very lowest levels at -130 dBm.

The leveling head reduces lead changes from 25 to just 5 during a typical calibration, allowing you to “connect once and test many,” extending unattended times in an automated system, and reducing connector wear.

Calibrated as a system to assure system performance

The 96040A is supplied with a 50 ohm leveling head. The /75 model has both 50 ohm and 75 ohm leveling heads. Each mainframe and head are calibrated together as a complete system. System calibration helps assure overall system performance. Each 96040A instrument is supplied with a comprehensive ISO 17025 compliant certificate of calibration with data for all key parameters, including level and attenuation, output VSWR, and phase noise. You can be assured that your 96040A is traceable, plus RF metrology and uncertainty analysis become much simpler and faster. Accredited certification is available for the 96040A and both 50 ohm and 75 ohm heads.

State-of-the-art phase noise performance

With reduced low phase noise optimized for low and high offset frequencies and specifications from 1 Hz to 10 MHz offsets, the 96040A offers exceptional phase noise performance beyond that required for today’s high performance workloads.

Phase noise data is included in the 96040A certificate of calibration. Instead of relying only on the more conservative guaranteed specifications, users have actual performance data for their unit. Even with the best low phase noise signal generators, filters are commonly used during spectrum analyzer phase noise calibration tests, reducing noise levels at wide (high) offset frequencies to improve test margins. The 9600FLT 1 GHz bandpass filter accessory is designed specifically for high performance spectrum analyzer wide-offset phase noise testing and connects easily to 96040A models in either benchtop or rack-mounted applications.

Selectable frequency reference input/ output expands functionality

Selectable external frequency reference input is available as a standard feature on the rear panel of the 96040A. The input allows you to lock the frequency output to an external reference, such as the Fluke Calibration 910R Rubidium Standard, for applications where high clock accuracy or use of a common reference frequency is important. The frequency reference output allows a DUT to be frequency locked to the 96040A internal reference clock. This configuration is often required to reduce frequency offset errors that may occur between the reference source and the DUT.

Simplify frequency response tests with 96040A sweep functions

RF applications often require a frequency sweep. The 96040A’s sweep functions simplify the application of manual legacy spectrum analyzer frequency response testing, as well as filter response measurements.

Automate with MET/CAL® software for “walk-away” efficiency

In a typical automated RF calibration process, the operator must frequently intervene to change test setups, thus limiting the benefits that can be realized by the automation. Walk-away automation can increase calibration system capacity by up to 25 percent using procedures you develop in MET/CAL  Calibration Management Software. For example, the manufacturer’s calibration procedure for calibrating the Agilent E4407B 26.5 GHz spectrum analyzer requires 27 different and complex test setups. On the other hand, the 96040A, used with MET/CAL  Calibration Management Software, can perform the major core of required tests with a single setup. Only six additional setups would be needed using a MET/CAL procedure.

MET/CAL procedures created by Fluke Calibration for the 9640A models can be used by the 96040A in 9640A emulation mode. Optimized automated procedures can save time for the operators by allowing them to leave the system running while attending to other work. For example, the E4407B MET/CAL procedure for the legacy 9640A, running in emulation mode on the 96040A, allows for a total 90 minutes of “walkaway” time within the total two-hour calibration runtime.

Using the 96040A with other automation solutions

The 96040A is also integrated easily into existing automated systems and software. The time savings and efficiency gains offered by the 96040A can be realized by structuring test sequences to take full advantage of its “connect once measure many” capabilities.

The 96040A is designed to match or exceed the performance and functionality of the HP3335A and HP8662/3A in calibration systems. With HP3335A and HP8662/3A GPIB command emulation as standard, replacing these popular but obsolete and difficult-to-maintain products becomes just a plug-and-play substitution.

96040A summary specifications*
  Frequency specifications Level specifications
(50 Ω output, see extended specifications for 75 Ω)
Range 1 mHz to 4 GHz -130 to +24 dBm to 125 MHz, 14 dBm at 4 GHz (leveled)
Resolution 10 µHz 0.001 dB
Accuracy ± 0.05 ppm ± 5 µHz Down to -48 dBm: ± 0.03 dB to 100 kHz, ± 0.05 dB to 128 MHz, ± 0.3 dB at 4 GHz
10 MHz to 128 MHz: ± 0.05 dB to -48 dBm, ± 0.1 dB to -84 dBm , ± 0.7 dB at -130 dBm
Attenuation   ± 0.02 dB to 49 dB, ± 0.15 dB at 110 dB
Relative to +10 dBm, 10 Hz to 128 MHz
VSWR ≤ 100 MHz: ≤ 1.05, ≤ 2 GHz: ≤ 1.1, 2 GHz to 4 GHz: ≤ 1.0 + 0.05 xf (GHz)
Harmonics and spurious –60 dBc harmonics, –78 dBc spurious to 1 GHz
Phase noise at 1 GHz –144 dBc/Hz, typical, at 10 kHz to 100 kHz offset
Modulation AM, FM, PM, internal and external. Frequency pull and external leveling
Frequency sweep 1 mHz to 4 GHz. Linear or Logarithmic. Stop-Start or Center-Span
Frequency counter Internal 50 MHz frequency counter
Temperature Operating: 0 °C to 50 °C, 23 °C ± 5 °C for specified performance; Storage: -20 °C to +70 °C.
Standard interfaces IEEE-488.2 (GPIB)
GPIB command emulation 9640A, 9640A-LPN, 9640A-LPNX, HP3335, HP8662A, HP8663A.
Dimensions (HxWxD) 146 mm x 442 mm x  551 mm (5.8 in x 17.4 in x 21.7 in) including handles Industry-standard 19 in (483 mm) rack mounting when fitted with Y9600 rack mounting kit
Weight 18 kg (40 lb)
*Key specifications summary. Refer to the extended specifications for full and detailed specifications.
Model Name Description
96040A

4 GHz RF Reference Source including 50 Ω Leveling Head

96040A/75

4 GHz RF Reference Source including 50 Ω and 75 Ω Leveling Heads

Accessories common to all models:

Accessory Description
9600FLT

1 GHz Wide Offset Phase Noise Filter

9600CONN

Adapter/Torque Kit

Y9600

Rackmount Kit (Slides)

96000CASE

 Rugged Transit Case

Priority Gold Instrument CarePlan

Fluke Calibration Priority Gold Instrument CarePlans are available for most calibration products. Please contact your local Fluke Calibration sales representative for details or to request a quote. You may also call the Customer Care Center at 877-355-3225 or send email to careplans@flukecal.com.

Silver CarePlan

Fluke Calibration Silver CarePlans are available for most calibration products. Please contact your local Fluke Calibration sales representative for details or to request a quote. You may also call the Customer Care Center at 877-355-3225 or send email to careplans@flukecal.com.

Product Manuals
application/pdf icon 96000 Series Operators Manual (7.22 MB)
application/pdf icon 96000 Series Operators Manual Supplement (513.64 KB)
application/pdf icon 96000 Series Operators Manual (chi) (5.27 MB)
application/pdf icon 96000 Series Operators Manual (fre) (7.34 MB)
application/pdf icon 96000 Series Operators Manual (ger) (4.74 MB)
application/pdf icon 96000シリーズ取扱説明書(日本語) (5.15 MB)
application/pdf icon 96000 Series Operators Manual (kor) (5.25 MB)
application/pdf icon 96000 Series Operators Manual (por) (4.75 MB)
application/pdf icon 96000 Series Operators Manual (rus) (5.29 MB)
application/pdf icon 96000 Series Operators Manual (spa) (4.73 MB)
application/pdf icon 96270A低相噪射频参考标准操作手册 (5.27 MB)
application/pdf icon 96000 Series Programmers Manual (1.14 MB)
application/pdf icon 96000 Series Programmers Manual Supplement (74.17 KB)
application/pdf icon 96000 Series Safety Information (155.73 KB)
application/pdf icon 96000 Series Safety Information (chi) (469.2 KB)
application/pdf icon 96000 Series Safety Information (fre) (98.08 KB)
application/pdf icon 96000 Series Safety Information (ger) (157.53 KB)
application/pdf icon 96000シリーズ安全情報 (日本語) (414.95 KB)
application/pdf icon 96000 Series Safety Information (kor) (467.28 KB)
application/pdf icon 96000 Series Safety Information (por) (142.37 KB)
application/pdf icon 96000 Series Safety Information (rus) (248.47 KB)
application/pdf icon 96000 Series Safety Information (spa) (108.7 KB)
application/pdf icon 96000 Series Service (8.57 MB)
application/pdf icon 96000 Series Service Supplement (603.56 KB)
application/pdf icon 96000, 96270A, 96040A Statement of Memory Volatility (61.06 KB)
application/pdf icon y9600 Instructions (543.1 KB)
Application Notes
application/pdf icon Applying RF correction factors correctly (2.13 MB)
application/pdf icon Choosing and using cables for RF calibration (2.16 MB)
application/pdf icon Making Repeatable RF Connections During RF Calibration (2.1 MB)
application/pdf icon Minimizing RF Mismatch Errors and Uncertainties (2.18 MB)
application/pdf icon Working with Power Splitters and Dividers (2.2 MB)
Data Sheets
application/pdf icon 96000 Series RF Reference Sources Extended Specifications (1.2 MB)
application/pdf icon 96270A低相噪射频参考标准技术指标 (1.63 MB)
application/pdf icon 96040A Low Phase Noise Reference Source Data Sheet (479.89 KB)
application/pdf icon 96040AReferenzquelle mit geringem Phasenrauschen (337.1 KB)
application/pdf icon 96040A Fuente de referencia de ruido de fase bajo (331.64 KB)
application/pdf icon 96040A Source de référence faible bruit de phase (324.35 KB)
application/pdf icon 96040A Fonte de referência com baixo ruído de fase (324.91 KB)
application/pdf icon 96040A Опорный источник с низким фазовым шумом (392.36 KB)
application/pdf icon 96040A 저위상 노이즈 레퍼런스 소스 (1.15 MB)
application/pdf icon 96040A 日本語テクニカル・データ (948.92 KB)
Firmware
96270A/96040 Firmware Update
Video
96270A 27 GHz Low Phase Noise Reference Source Introduction (Video)
96270A RF Reference Source and MET/CAL Software: Calibrating a Spectrum Analyzer (Long Version)
  • Printer-friendly version »
  • Home
  • Products
    • New Products
    • Electrical Calibration
      • Electrical Standards
      • Electrical Calibrators
      • Bench Multimeters
      • Electrical Calibration Software
    • RF Calibration
      • RF Reference Sources
      • RF Calibration Accessories
      • RF Calibration Software
    • Data Acquisition and Test Equipment
      • Bench Multimeters
      • Data Acquisition
      • Data Acquisition Software
    • Temperature Calibration
      • ITS-90 Temperature Standards
        • ITS-90 Fixed-point cells
        • Standard Platinum Resistance Thermometers
        • Maintenance Apparatus
        • Liquid Nitrogen Comparison Calibrator
        • Resistance Bridges
        • Standard Resistors
      • Calibration Baths
        • Compact Calibration Baths
        • Standard Calibration Baths
        • Special Application Baths
        • Bath Accessories
        • Bath Controllers
        • Bath Fluids
      • Industrial Calibrators
        • Field Metrology Wells
        • Metrology Wells
        • Handheld Calibrators
        • Field Dry-Block Calibrators
        • Micro Baths
        • Infrared Calibrators
        • Thermocouple Furnaces
        • Dual Block Dry-Well
        • Zero-point Dry-Well
      • Probes / Sensors
        • Platinum Resistance Thermometers (PRTs)
        • Thermistors
        • Thermocouples
      • Digital Thermometer Readouts
      • Multifunction Calibrators
      • Temperature Calibration Software
    • Humidity Calibration
      • Humidity Generators
      • Humidity Data Loggers and Monitors
    • Pressure Calibration
      • Piston Gauges
        • NMI Piston Gauges
        • Absolute Piston Gauges
        • High Pressure Pneumatic Piston Gauges
        • Hydraulic Piston Gauges
        • Piston Gauge Accessories
      • Automated Pressure Controller / Calibrators
        • Low Pressure Controllers / Calibrators
        • Pneumatic Pressure Controllers / Calibrators
        • High Pressure Pneumatic Controller / Calibrators
        • Hydraulic Controller / Calibrators
      • Pressure Monitors
        • Low Pressure Monitors
        • Digital Pressure Gauges
        • Reference Pressure Monitors
      • Deadweight Testers
        • Pneumatic Deadweight Testers
        • Oil Deadweight Testers
        • Water Deadweight Testers
        • High-Pressure Hydraulic Deadweight Testers
        • Deadweight Tester Accessories
      • Manual Pressure Calibration
        • Pressure Calibrators
        • Pneumatic Pressure Control
        • Hydraulic Pressure Comparators / Pumps
      • Handheld Pressure Calibrators
      • Air Data Calibration
      • Environmental Monitors
      • Pressure Calibration Accessories
      • Pressure Calibration Custom Systems
      • Pressure Calibration Software
    • Flow Calibration
      • Gas Flow Standards
      • Gas Flow Accessories
      • GFS Primary Gravimetric Flow Standard
      • Flow Calibration Software
    • Process Calibration Tools
      • Temperature Calibrators
        • Handheld Temperature Calibrators
        • Dry-Block Calibrators and Micro-Baths
        • Precision Digital Thermometers
        • Temperature Probes
        • Infrared Calibrators
        • Hygro Thermometer with Data Logging
      • Pressure Calibrators
        • Digital Pressure Calibrators
        • Handheld Pressure Calibrators
        • Deadweight Testers
        • Precision Digital Pressure Gauges
        • Calibration Hand Pumps
      • Multifunction Calibrators
      • mA Loop Calibrators
      • Process Calibration Software
    • Calibration Software
      • MET/CAL® Software
      • MET/CAL® Support
      • Asset Management Software
      • Temperature Calibration Software
      • Pressure Calibration Software
      • Flow Calibration Software
      • Mechanical / Dimensional Calibration Software
    • Service and Support
    • All Calibration Instruments
    • Handheld Test Tools
  • Purchase Info
    • Where to Buy
    • Request a Quote
    • Request a Demo
    • Request a Sales Consultation
    • Certified Pre-Owned Equipment
    • General Services Administration (GSA)
    • Financing Program
    • National Stock Numbers (NSNs)
    • Payment Options and Tax Info
  • News
    • Press Releases
    • Promotions
    • Industry Links
    • Metrology Salary Survey
  • Training and Events
    • Conferences and Exhibitions
    • Training Courses
    • User Group Meetings
    • Web Seminars
      • Live Seminars
      • On-Demand Seminars
  • Literature and Education
    • Education Hub
    • About Calibration
    • Articles and Education
    • Product Literature
    • Product Manuals (User Guides)
    • Videos and Virtual Demos
    • Resource Centers
    • Blog
  • Service and Support
    • Service Request (RMA)
    • Service Plans
    • Technical Support
    • Knowledge Base
    • Accreditations
    • Authorized Service Centers
    • Calibration Certificates
    • Community Forum
    • My MET/SUPPORT
      • Activate
      • Procedures
      • Software
      • Technical Bulletins
      • Priority Support
      • Manuals
    • Product Manuals (User Guides)
    • Safety Data Sheets (SDS)
    • Recycle Program
    • Safety, Service, and Product Notices
    • Software Downloads
    • Warranties
    • Tools
      • PT100 Calculator
      • ITS-90 Reference Function Calculator
      • Thermocouple Table Voltage Calculator
      • Thermocouple Voltage to Temperature Calculator
  • About Us
    • Contact Us
    • Visit Us
    • Employment
    • Fluke Calibration
      • Hart Scientific Temperature Calibration
      • DH Instruments Pressure and Flow Calibration
      • Pressurements Pressure Calibration
      • Ruska Pressure Calibration
    • Fluke Companies
    • Integrity and Compliance
    • Frequently Asked Questions
    • Why buy Fluke Calibration ?
Home|Products|RF Calibration|RF Reference Sources|96040A Low Phase Noise Reference Source

Sidebar Request a Quote

Request a quote

Your information is protected by our privacy policy.

©1995-2023 Fluke Corporation
             

Secondary menu

  • Disclaimer
  • Privacy Statement
  • Terms of Use
  • Terms of Sale