Made from the finest platinum and platinum-rhodium alloy, these type R thermocouples and type S thermocouples cover a temperature range of 0 °C to 1450 °C with uncertainties as good as 0.15 °C over most of that range. With four different models for each type, we have the type R thermocouple and type S thermocouple to fit your application.
Eight models to fit any type R or S thermocouple application
- Designed by the Fluke Calibration primary temperature standards design team
- Two sizes available, each with or without reference junction
- Four-point calibration by fixed point (Sn, Zn, AI, Ag) extrapolated to 1450 °C
The measuring junction of both the 5649 and the 5650 is encased in a 0.25-inch (6.35 mm) alumina sheath that can be ordered in lengths of 20 or 25 inches (50.8 or 63.5 cm) to fit the specific requirements of your application. A reference, or “cold," junction may also be ordered. The reference junction uses a stainless steel sheath and is 8.25 inches long (21 cm) by 0.188 inches in diameter (4.8 mm). The thin diameter minimizes the immersion depth needed, but the extra length ensures you can get all the immersion you like.
Special tin-plated, solid-copper connecting wires with ultra-low EMF properties are used to help retain the integrity of your measurement junction where the probe attaches to your micro voltmeter or Hart Black Stack.
Each probe comes with an individual calibration with fixed-point standards to reduce uncertainties to ± 0.15 °C up to 962°C, ± 0.25 °C up to 1100 °C, and increasing linearly to ± 2.0 °C at 1450 °C.
The probe assembly can be easily disassembled for performing your own bare-wire calibrations.
Specifications |
|
Range | 0 °C to 1450 °C |
Type | Platinum/13 % Rhodium vs. platinum (type R) Platinum/10 % Rhodium vs. platinum (type S) |
Calibration | Fixed point calibration uncertainties (k=2): ± 0.15 °C up to 962 °C, increasing linearly to ± 2.0 °C at 1450 °C |
Hot Junction Sheath Dimensions |
6.35 mm (0.25 in) diameter; see Ordering Information for lengths |
Reference Junction Sheath Dimensions | 4.8 mm dia. x 210 mm long (0.188 x 8.25 in) |
Long-Term Stability | ± 0.5 °C to 1100 °C ± 2.0 °C to 1450 °C (over one year depending on usage) |
Short-Term Stabilities | ± 0.2 °C to 1100 °C ± 0.6 °C to 1450 °C |
Immersion | At least 152 mm (6 in) recommended |
Protective Case | Model 2609 case included |
Weight | 1 kg (2 lb) |
Model Name | Description |
---|---|
5649-20-X |
Type R TC, 508 mm (20 in) X = termination. Specify “B" (bare wire), “W" (generic copper-to-copper TC connector), or “R" (standard Type R/S TC connector). Models with reference junctions should not specify “R" and models without reference junctions should not specify “W". |
5649-20CX |
Type R TC, 508 mm (20 in), with reference junction X = termination. Specify “B" (bare wire), “W" (generic copper-to-copper TC connector), or “R" (standard Type R/S TC connector). Models with reference junctions should not specify “R" and models without reference junctions should not specify “W". |
5649-25-X |
Type R TC, 635 mm (25 in) X = termination. Specify “B" (bare wire), “W" (generic copper-to-copper TC connector), or “R" (standard Type R/S TC connector). Models with reference junctions should not specify “R" and models without reference junctions should not specify “W". |
5649-25CX |
Type R TC, 635 mm (25 in), with reference junction X = termination. Specify “B" (bare wire), “W" (generic copper-to-copper TC connector), or “R" (standard Type R/S TC connector). Models with reference junctions should not specify “R" and models without reference junctions should not specify “W".
|
5650-20-X |
Type S TC, 508 mm (20 in) X = termination. Specify “B" (bare wire), “W" (generic copper-to-copper TC connector), or “R" (standard Type R/S TC connector). Models with reference junctions should not specify “R" and models without reference junctions should not specify “W". |
5650-20CX |
Type S TC, 508 mm (20 in), with reference junction X = termination. Specify “B" (bare wire), “W" (generic copper-to-copper TC connector), or “R" (standard Type R/S TC connector). Models with reference junctions should not specify “R" and models without reference junctions should not specify “W". |
5650-25-X |
Type S TC, 635 mm (25 in) X = termination. Specify “B" (bare wire), “W" (generic copper-to-copper TC connector), or “R" (standard Type R/S TC connector). Models with reference junctions should not specify “R" and models without reference junctions should not specify “W". |
5650-25CX |
Type S TC, 635 mm (25 in), with reference junction X = termination. Specify “B" (bare wire), “W" (generic copper-to-copper TC connector), or “R" (standard Type R/S TC connector). Models with reference junctions should not specify “R" and models without reference junctions should not specify “W". |
Accessories common to all models:
Accessory | Description |
---|---|
2609 |
Probe Carrying Case, Plastic (for probes 635 mm [25 in] in length) |
Product Manuals |
---|
Application Notes |
---|
Papers / Articles |
---|
On-Demand Webinars |
---|
Como Realizar un Sistema de Calibración para Termopares |
- Home
- Products
- New Products
- Electrical Calibration
- RF Calibration
- Data Acquisition and Test Equipment
- Temperature Calibration
- Humidity Calibration
- Pressure Calibration
- Flow Calibration
- Process Calibration Tools
- Calibration Software
- Service and Support
- All Calibration Instruments
- Handheld Test Tools
- Purchase Info
- News
- Training and Events
- Literature and Education
- Service and Support
- Service Request (RMA)
- Service Plans
- Technical Support
- Knowledge Base
- Accreditations
- Authorized Service Centers
- Calibration Certificates
- Community Forum
- My MET/SUPPORT
- Product Manuals (User Guides)
- Safety Data Sheets (SDS)
- Recycle Program
- Safety, Service, and Product Notices
- Software Downloads
- Warranties
- Tools
- About Us
Sidebar Request a Quote
Request a quote