• Other Fluke companies:
  • Fluke
  • Fluke Biomedical
  • Fluke Networks
  • Fluke Process Instruments
See more Fluke brands
Accelix Amprobe Beha-Amprobe Comark Emaint Landauer Pacific Laser Systems Pomona RaySafe Schad
Home
Precision, Performance, Confidence.
Fluke Calibration: Europe
  • Register
  • Log in
  • Contact Us

EU - English [Change]

 

Get Quote

8270A and 8370A Modular High-Pressure Controllers / Calibrators

Fluke 8270A High Pressure Controller / Calibrator
Fluke 8370A High Pressure Controller / Calibrator
Fluke Calibration 8370A High Pressure Controller / Calibrator with CPS
Fluke 8270A High Pressure Controller / Calibrator
Fluke 8370A High Pressure Controller / Calibrator
Fluke Calibration 8370A High Pressure Controller / Calibrator with CPS
Request a quote
Watch the video
  • Highlights
  • Description
  • Specifications
  • Models and Accessories
  • Knowledge and Information

Widest workload coverage in an automated high-pressure controller

The 8270A and 8370A are automated pneumatic high-pressure controllers that calibrate a wide workload of pressure sensors, covering twice the pressure ranges at twice the speed of other high-pressure controllers.  Two models let you balance price and performance:
  • The 8270A measures and controls pressures from vacuum to 44 MPa (6400 psi).  It can be configured with ranges as low as 100 kPa (15 psi).
  • The 8370A measures and controls pressures from atmosphere to 107 MPa (15 500 psi).  It can be configured with ranges as low as 700 kPa (100 psi).
Fluke Calibration’s unique control technology enables you to use these calibrators at low or high pressures, all in the same instrument. Control precision is 0.002% of active range.  
 
Expand workload coverage to both gas and liquid filled devices by using the optional Contamination Prevention System (CPS).

100:1 control turndown

A pressure range 100 times smaller than the full scale will meet the control specifications without reducing supply pressure.  For example, an 8370A with a 70 MPa (10 000 psi) high range module and a 700 kPa (100 psi) low range module will be able to control pressures below 700 kPa (100 psi) to within ±0.014 kPa (0.002 psi) without reducing the supply pressure.
 

Flexible configuration options

The 8270A and 8370A are modular systems that can be configured with up to five measurement modules at the same time, so they can handle high pressure, low pressure, and everything in between. Three families of modules provide three levels of performance that let you set up a system matching your needs for accuracy and value.
 
Good: PM200 Pressure Measurement Modules Better: PM500 Pressure Measurement Modules Best: PM600 Measurement Modules
  • 0.02% FS specification makes it ideal for calibrating or testing pressure dial gauges, lower accuracy transmitters, or pressure switches
  • Rugged silicon pressure sensor design allows for faster control
  • Economic price point helps facilitate the purchase of backup modules, making sure you are never down for calibration
  • Highly characterized and linearized silicon pressure sensor provides an economical way of making accurate pressure measurements
  • 0.01% reading measurement uncertainty from 50% to 100% for most ranges allows for wide workload coverage
  • More than 45 ranges, from low pressures up to 20 MPa (3000 psi) to choose from. Your application is covered with this wide flexibility in configuration.
  • Fluke Calibration Quartz Reference Pressure Transducer (Q-RPT) technology provides precise measurement with long term stability
  • 0.01% reading measurement uncertainty from 30% to 100% of the modules’ span allows for extremely wide workload coverage
  • Onboard barometer included with absolute mode modules, allowing them to be used in both absolute and gauge mode

Modern replacements for hydraulic deadweight testers and comparators

Safety: the number one priority

Safety is the top priority in the design and manufacture of our pressure products, especially high-pressure pneumatic controllers.  The 8270A and 8370A meet all appropriate safety standards.  Each unit is equipped with over-pressure protection as well as a front-panel abort button.  Pressing the abort button vents the test pressure and returns the unit to a safe condition.  Additionally, an abort valve accessory allows for faster, directed vent, as well as automated venting at loss of power.  High-pressure gas does have more stored energy than high-pressure oil, but it is a safe option under the right conditions.  By using the 8270A or 8370A with the available accessories, you have safe operation with a clean pressure media.

Calibrate oil or gas devices without risk of contamination

The 8270A and 8370A, coupled with the optional CPS, can calibrate both gas-filled and liquid-filled devices without concern of contamination.  With its wide pressure range coverage, one controller can accomplish the task that used to require two separate standards.

Easiest to use high-pressure standards available

Automated pressure controllers are some of the simplest, easiest-to-use pressure standards.  Controlling and measuring pressure is as simple as typing in the required pressure and pressing Enter.  Unlike deadweight testers, you do not need to spin weights at a particular speed or calculate gravity or temperature corrections.  Unlike pressure comparators, the process can be fully automated and stability is achieved and maintained in a fraction of the time.

Flexibility to handle a wide variety of applications and workloads

The 8270A and 8370A can be configured with different classes of modules with different pressure ranges.  This gives you flexibility to handle a variety of applications and workloads.  Uncertainties as good as 0.01 % reading are available across the vast majority of the range, making it an ideal replacement for deadweight testers.

An affordable solution that can grow as your requirements do

With their wide pressure range coverage, the 8270A and 8370A can replace multiple standards at once.  Thanks to the modular design, pressure ranges and capabilities can be added at any time, allowing for lower cost of entry in favor of future expansion, growing with your needs.

Ideal for characterization or calibration in production processes 

Whether you manufacture large batches of low cost pressure sensors or customized, expensive pressure sensors for aerospace and other mission critical applications, the 8270A and 8370A are ideal for use in your production line.

Robust design provides unsurpassed control performance

The 8270A and 8370A make use of our unique pressure control technology, first developed to handle some of the harshest pressure calibration applications.  This technology provides unsurpassed control performance over a wide pressure range over an extended life cycle, reducing your downtime and maintenance costs.

Modularity makes maintenance a snap

The 8270A and 8370A make use of Fluke Calibration’s modular platform design.  Measurement and control modules can be easily removed through the front panel to simplify maintenance or re-ranging requirements.

Control speed meets the demands of a manufacturing environment

With times to setpoint as low as 30 seconds, the 8270A and 8370A can control pressures faster than traditional high-pressure controllers can.  

Support for remote communication and automation

The 8270A and 8370A support remote communication over RS-232, GPIB, USB, and ethernet connections.  Using either the native SCPI protocol or a variety of emulation modes, these controllers can be used in a wide range of automated processes.

Clean operation to 100 MPa (15 000 psi) 

The wide pressure range control allows you to use the same test station for low, medium, or high-pressure work.  By using a pneumatic pressure controller in your production process, you can provide your customers with a clean product, free of oil contamination.

Automate with COMPASS® software

COMPASS for Pressure software enables you to automate the 8370A and 8270A and run complete pressure calibration sequences on single or multiple devices under test (DUTs). The 8270A and 8270A feature a full remote interface that also lets you use it with custom software or other data acquisition equipment.

Support and services when you need them

Fluke Calibration offers testing, repair and calibration services to meet your needs quickly and at a fair cost while maintaining the high level of quality that you expect. Our pressure calibration laboratories are accredited for conformance to ISO Guide 17025 and we maintain global calibration and repair facilities.

Get peace of mind and uptime with a Gold CarePlan

A Priority Gold Instrument CarePlan gives you peace of mind and maximum uptime from the people who know your Fluke product best. It includes an expedited annual calibration and extended warranty to help you reduce downtime by a week1 and get the best performance from your instruments.  Choose from one-year, three-year or five-year CarePlans. (Note: Priority shipping times vary by country. Contact your local Fluke Calibration sales representative for details.)

Training options help you to get the most from your investment

Fluke Calibration sponsors pressure and flow calibration courses for both novice and expert pressure calibration professionals in our Phoenix, Arizona facility. We also host a series of free webinars about a wide variety of pressure calibration topics. If you need training to help you maintain your fleet of pressure controllers, we can help you there too.

PM200 Pressure Measurement Modules Performance Specifications

PM500 Pressure Measurement Modules Performance Specifications

PM600 Pressure Measurement Modules Performance Specifications

General specifications
Mains
Power requirements 100 V ac to 240 V ac, 47 Hz to 63 Hz
Fuse T 2 A, 250 V
Max power consumption 100 W
Environment
Operating ambient temperature range 15 °C to 35 °C
Storage temperature -20 °C to 70 °C
Relative humidity Operating: <80 % to 30 °C, <70 % to 40 °C
Storage: <95 %, non-condensing. A power stabilization period of four days may be required after extended storage at high temperature and humidity.
Vibration MIL-T-28800E
Altitude (operation) <3000 m
Warm up time 15 minutes after power up or module installation, when items previously stored within Operating Ambient Temperature Range.
Compliance
Ingress protection IEC 60529:IP20
Safety IEC 61010-1, Installation Category II, Pollution degree 2
Weight and Dimensions
Weight (Chassis only) 13 kg (28.5 lbs) / 15 kg (35.25 lbs)
Dimensions Height: 147 mm (5.78 in)
Width: 452 mm (17.79 in)
Depth 488 mm (19.2 in)
Rack mount dimensions 3U-19 inch rack
Electromagnetic Compatibility (EMC)
IEC 61326-1 (Controlled EM environment IEC 61326-2-1; CIPR 11: Group 1, Class A
Group 1 equipment has intentionally generated and/or uses conductivity coupled radio-frequency energy which is necessary for the internal functioning of the equipment itself.

Class A equipment is equipment suitable for use in all establishments other than domestic and those directly connected to a low voltage power supply network which supplies buildings used for domestic purposes.

Emissions which exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. The equipment may not meet the immunity requirements of 61326-1 when test leads and/or test probes are connected.

USA (FCC) 47 CFR 15 subpart B, this product is considered an exempt device per clause 15.103.
Korea (KCC) Class A Equipment (Industrial Broadcasting & Communication Equipment)
This product meets requirements for industrial (Class A) electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
Communication Interfaces
Primary Remote Interfaces IEEE, Ethernet, RS-232, USB
System Connection Supports interconnection of 2 or 3 systems
Switch Test Connection Standard BNC Jack:
Nominal 24 V dc isolated drive
Maximum 30 V dc w.r.t.chassis ground
Aux Drivers 4 external Solenoid Drivers
24 V dc Drive (Maximum drive 6 W continuous per channel
Operating characteristics
Control specifications
95 % of setpoints are within specification limits for stated conditions as calculated by mean plus 1.67 standard deviations of test data.
Control Precision (Dynamic Mode) 0.002% Range Span or 0.01 kPa (whichever is greater)
Control Turndown 100:1 (typical)

To meet the control specifications, supply pressure should not be greater than 100 times the range of the measurement module. Control turndown is defined as the relationship between the provided supply pressure and the appropriate supply pressure for the range

Low Control Point 1 kPa (0.15 psi) absolute (8270A only)
7 kPa (1.0 psi) gauge (8370A, 8270A without vacuum pump)
Settling Time Settling time is the time required to be within 0.005% of setpoint for 10 % steps into volumes up to 50 cm3 for all pressures >7 kPa absolute (8270A) or 7 kPa gauge (8370A). Settling time may be affected by multiple variables, including temperature effects, component flow rates, leaks, and overall volume configurations.

Pressure Measurement Module (PMM) Dynamic A Mode 1 Dynamic B Mode
Range < 44 MPa  Range > 44 MPa Range < 44 MPa Range > 44 MPa
PM200/PM230 30 seconds 45 seconds 60 seconds 75 seconds
PM500 35 seconds -- 60 seconds --
PM600/PM630; 45 seconds 60 seconds 60 seconds 75 seconds
1 8270A: Settling time for setpoints less than or equal to 200 kPa absolute may require an additional 15 seconds.
8370A: Settling time for setpoints less than or equal to 700kPa gauge may require an additional 15 seconds.
Overshoot (Dynamic A) 0.08% Full Scale or 2 kPa (whichever is greater)
Overshoot (Dynamic B) 0.008% Full Scale or 2 kPa (whichever is greater)
Pressure Limits
Supply Port (8270A/8370A) Maximum 48 MPa (7 000 psi) gauge / 110 MPa (16 000 psi) gauge
Minimum 2 MPa (300 psi) gauge for 8270A and 8370A
Test Port (8270A/8370A) 44 MPa (6 400 psi) gauge / 107 MPa (15 500 psi) gauge
Reference Port 150 kPa (22 psi) absolute
Vent Port 150 kPa (22 psi) absolute
Relief Valves/Rupture Disk
8270A Chassis Supply port relief valve is set to 52 MPa (7 500 psi)

8370A Chassis Supply has a rupture disk installed which is designed to burst at
152 MPa (22 000 psi). Low pressure manifold relief valve is set to
52 MPa (7 500 psi).

Modules with full scales ≤ 44 MPa include pressure relief valves

Supply Gas Type
Clean Dry Nitrogen, Helium, Argon, or Air - Industrial Grade Nitrogen, 99.5%+
Vacuum Supply
>50 liters per minute capacity with Auto Vent feature

System will exhaust gas through the vacuum system when controlling down in pressure. Appropriate protections are necessary.

Model Name Description
8370A-2

High-Pressure Modular Controller Chassis, 2 Bay, 100 MPa (15 000 psi)

8370A-5

High-Pressure Modular Controller Chassis, 5 Bay, 100 MPa (15 000 psi)

8370A-2-PCM

High-Pressure Modular Controller, 2-Bay, W/PCM 

8370A-5-PCM

High-Pressure Modular Controller, 5-Bay, W/PCM

8270A-2-BSP

Modular Pressure Controller Chassis, 2 Bay, BSP Manifold

8270A-2-BSP-PCM

Modular Pressure Controller, 2-Bay, BSP, W/PCM   

8270A-5-BSP-PCM

Modular Pressure Controller, 5-Bay, BSP, W/PCM

8270A-2-NPT

Modular Pressure Controller Chassis, 2 Bay, NPT Manifold

8270A-2-NPT-PCM

Modular Pressure Controller, 2-Bay, NPT, W/PCM

8270A-5-NPT-PCM

Modular Pressure Controller, 5-Bay, NPT, W/PCM

8270A-2-SAE

Modular Pressure Controller Chassis, 2 Bay, 7/16-20 Manifold

8270A-2-SAE-PCM

Modular Pressure Controller, 2-Bay, SAE, W/PCM 

8270A-5-SAE-PCM

Modular Pressure Controller, 5-Bay, SAE, W/PCM

8270A-5-BSP

Modular Pressure Controller Chassis, 5 Bay, BSP Manifold

8270A-5-NPT

Modular Pressure Controller Chassis, 5 Bay, NPT Manifold

PCM-STD-100M

High-Pressure Control Module, Standard Turndown, 100 MPa (15 000 psi)

PCM-STD-40M

Pressure Control Module, 827X, Standard Turndown, 40 MPa (6000 psi)

Accessories common to all models:

Accessory Description
PM200 Pressure Measurement Modules

For 2271A Industrial Pressure Calibrator, and 6270A, 8270A  and 8370A Pressure Controller/Calibrators

PM500 Pressure Measurement Modules

For 2271A Industrial Pressure Calibrator and 6270A, 8270A and 8370A Pressure Controller / Calibrators 

PM600 Pressure Measurement Modules

For 6270A, 8270A and 8370A Pressure Controller/Calibrators

CPS-100M

High-Pressure Contamination Prevention System, Std Port/Adptrs

CPS-40M-HC40

Contamination Prevention System, 40 MPa (6000 psi), with HC40 test port and hand tight adaptors

SPLT-40M

Self-Purging Liquid Trap

PK-8270-BSP

Lines and Fittings Kit, 8270A BSP

PK-8270-NPT

Lines and Fittings Kit, 8270A NPT

PK-8270-SAE

Lines and Fittings Kit, 8270A 7/16-20

PK-8370-100M

Lines and Fittings Kit, 837X

TST-100M

High-Pressure Test Station, Std Port/Adaptors

TST-40M-HC40

Test Station, Std Port/Adaptors

GBK-110M

Gas Booster Kit, 152:1, 110 MPA (16 000 PSI)

GBK-50M

Gas Booster Kit, 75:1, 50 MPA (7300 PSI)

VA-PPC/MPC-REF-110

Vacuum Pump Package, 110 V

VA-PPC/MPC-REF-220

Vacuum Pump Package, 220 V AC

CASE-PMM

Shipping Case, 3 PMM Modules

CASE-XX70

Reusable Transit Case for XX70

KIT-PMM-CAL-100M

High-Pressure Measurement Module Calibration Kit

KIT-PMM-CAL-40M

Pressure Measurement Module Calibration Kit

CDG-REF-1TORR
Capacitance Diaphragm Gauge for zeroing of Absolute Mode PM500 Modules
PK-PMM-ZERO

Interconnection Kit for zeroing of Absolute Mode PM500 Modules

RMK-XX70

Rack mount Kit, 19 In Width, 3U

PK-VLV-ABORT-100M

Kit, High-Pressure Abort Valve

PK-VLV-ISO-100M

Kit, High-Pressure Isolation Valve

PK-VLV-ISO-40M

Kit, Pressure Isolation Valve

6270-SYS-CBL

6270A System Cable Kit

KIT-EMM300

Electrical Measurement Module with Docking Station

DS70-KIT-EMM

Electrical Measurement Module Docking Station

EMM300

Electrical Measurement Module

SK-8270-SERVICE

Seals Kit, 8270 Service

SK-8370-SERVICE

Seals Kit, 8370 Service

Product Manuals
application/pdf icon 6270A, 8270A, 8370A Programmers Reference Guide (546.31 KB)
application/pdf icon 8270A/8370A Operators (2.3 MB)
application/pdf icon 8270A/8370A Operators (chi) (2.65 MB)
application/pdf icon 8270A/8370A Operators (fre) (2.6 MB)
application/pdf icon 8270A/8370A Operators (ger) (2.66 MB)
application/pdf icon 8270A/8370A Operators (ita) (2.42 MB)
application/pdf icon 8270A/8370A Operators (jpn) (2.52 MB)
application/pdf icon 8270A/8370A Operators (kor) (2.65 MB)
application/pdf icon 8270A/8370A Operators (por) (2.45 MB)
application/pdf icon 8270A/8370A Operators (rus) (2.56 MB)
application/pdf icon 8270A/8370A Operators (spa) (2.55 MB)
application/pdf icon 8270A/8370A Product Specifications (238.21 KB)
application/pdf icon 8270A/8370A Product Specifications (chi) (337.47 KB)
application/pdf icon 8270A/8370A Product Specifications (fre) (243.28 KB)
application/pdf icon 8270A/8370A Product Specifications (ger) (248.28 KB)
application/pdf icon 8270A/8370A Product Specifications (ita) (243.45 KB)
application/pdf icon 8270A/8370A Product Specifications (jpn) (348.8 KB)
application/pdf icon 8270A/8370A Product Specifications (kor) (304.83 KB)
application/pdf icon 8270A/8370A Product Specifications (por) (244.2 KB)
application/pdf icon 8270A/8370A Product Specifications (rus) (244.9 KB)
application/pdf icon 8270A/8370A Product Specifications (spa) (244.53 KB)
application/pdf icon 8270A/8370A Safety Information (2.11 MB)
application/pdf icon 8270A/8370A Safety Information (fre) (2.6 MB)
application/pdf icon 8270A/8370A Safety Information (ger) (2.6 MB)
application/pdf icon 8270A/8370A Safety Information (ita) (2.59 MB)
application/pdf icon 8270A/8370A Safety Information (jpn) (1.81 MB)
application/pdf icon 8270A/8370A Safety Information (kor) (2.75 MB)
application/pdf icon 8270A/8370A Safety Information (por) (2.59 MB)
application/pdf icon 8270A/8370A Safety Information (rus) (2.53 MB)
application/pdf icon 8270A/8370A Safety Information (spa) (2.59 MB)
application/pdf icon CPS-40M-HC40/CPS-100 Instructions (715.74 KB)
application/pdf icon CPS-40M-HC40/CPS-100 Instructions (chi) (785.18 KB)
application/pdf icon CPS-40M-HC40/CPS-100 Instructions (fre) (730.23 KB)
application/pdf icon CPS-40M-HC40/CPS-100 Instructions (ger) (734.68 KB)
application/pdf icon CPS-40M-HC40/CPS-100 Instructions (ita) (727.3 KB)
application/pdf icon CPS-40M-HC40/CPS-100 Instructions (jpn) (846.69 KB)
application/pdf icon CPS-40M-HC40/CPS-100 Instructions (kor) (882.66 KB)
application/pdf icon CPS-40M-HC40/CPS-100 Instructions (por) (732.62 KB)
application/pdf icon CPS-40M-HC40/CPS-100 Instructions (rus) (710.99 KB)
application/pdf icon CPS-40M-HC40/CPS-100 Instructions (spa) (732.64 KB)
application/pdf icon GBK-50M/GBK-110M Instruction (eng) (499.39 KB)
application/pdf icon GBK-50M/GBK-110M Instruction (chi) (606.26 KB)
application/pdf icon GBK-50M/GBK-110M Instruction (fre) (506.35 KB)
application/pdf icon GBK-50M/GBK-110M Instruction (ger) (524.54 KB)
application/pdf icon GBK-50M/GBK-110M Instruction (ita) (499.79 KB)
application/pdf icon GBK-50M/GBK-110M Instruction (jpn) (620.45 KB)
application/pdf icon GBK-50M/GBK-110M Instruction (kor) (615.99 KB)
application/pdf icon GBK-50M/GBK-110M Instruction (por) (504.91 KB)
application/pdf icon GBK-50M/GBK-110M Instruction (rus) (630.23 KB)
application/pdf icon GBK-50M/GBK-110M Instruction (spa) (497.36 KB)
application/pdf icon KIT-EMM300 Instructions (588.55 KB)
application/pdf icon KIT-EMM300 Instructions (chi) (926.29 KB)
application/pdf icon KIT-EMM300 Instructions (fre) (598.5 KB)
application/pdf icon KIT-EMM300 Instructions (ger) (623.99 KB)
application/pdf icon KIT-EMM300 Instructions (ita) (594.39 KB)
application/pdf icon KIT-EMM300 Instructions (jpn) (845.97 KB)
application/pdf icon KIT-EMM300 Instructions (kor) (850.6 KB)
application/pdf icon KIT-EMM300 Instructions (por) (598.6 KB)
application/pdf icon KIT-EMM300 Instructions (rus) (560.73 KB)
application/pdf icon KIT-EMM300 Instructions (spa) (600.15 KB)
application/pdf icon PK-8270-X/PK-8370-X Lines & Fittings Kit Instructions (2.94 MB)
application/pdf icon PK-8270-X/PK-8370-X Lines & Fittings Kit Instructions (chi) (1.95 MB)
application/pdf icon PK-8270-X/PK-8370-X Lines & Fittings Kit Instructions (fre) (2.94 MB)
application/pdf icon PK-8270-X/PK-8370-X Lines & Fittings Kit Instructions (ger) (2.94 MB)
application/pdf icon PK-8270-X/PK-8370-X Lines & Fittings Kit Instructions (ita) (2.94 MB)
application/pdf icon PK-8270-X/PK-8370-X Lines & Fittings Kit Instructions (jpn) (2.03 MB)
application/pdf icon PK-8270-X/PK-8370-X Lines & Fittings Kit Instructions (kor) (3.07 MB)
application/pdf icon PK-8270-X/PK-8370-X Lines & Fittings Kit Instructions (por) (2.94 MB)
application/pdf icon PK-8270-X/PK-8370-X Lines & Fittings Kit Instructions (rus) (2.7 MB)
application/pdf icon PK-8270-X/PK-8370-X Lines & Fittings Kit Instructions (spa) (2.94 MB)
application/pdf icon PK-VLV-ABORT-100M, PK-VLV-ISO-40M, PK-VLV-ISO-100M Instruction (438.31 KB)
application/pdf icon PK-VLV-ABORT-100M, PK-VLV-ISO-40M, PK-VLV-ISO-100M Instruction (chi) (478.43 KB)
application/pdf icon PK-VLV-ABORT-100M, PK-VLV-ISO-40M, PK-VLV-ISO-100M Instruction (fre) (443.47 KB)
application/pdf icon PK-VLV-ABORT-100M, PK-VLV-ISO-40M, PK-VLV-ISO-100M Instruction (ger) (446.04 KB)
application/pdf icon PK-VLV-ABORT-100M, PK-VLV-ISO-40M, PK-VLV-ISO-100M Instruction (ita) (362.28 KB)
application/pdf icon PK-VLV-ABORT-100M, PK-VLV-ISO-40M, PK-VLV-ISO-100M Instruction (jpn) (545.81 KB)
application/pdf icon PK-VLV-ABORT-100M, PK-VLV-ISO-40M, PK-VLV-ISO-100M Instruction (kor) (531.7 KB)
application/pdf icon PK-VLV-ABORT-100M, PK-VLV-ISO-40M, PK-VLV-ISO-100M Instruction (por) (444.33 KB)
application/pdf icon PK-VLV-ABORT-100M, PK-VLV-ISO-40M, PK-VLV-ISO-100M Instruction (rus) (479.73 KB)
application/pdf icon PK-VLV-ABORT-100M, PK-VLV-ISO-40M, PK-VLV-ISO-100M Instruction (spa) (444.17 KB)
application/pdf icon SPLT-40M Instructions (344.06 KB)
application/pdf icon SPLT-40M Instructions (chi) (406.28 KB)
application/pdf icon SPLT-40M Instructions (fre) (353.17 KB)
application/pdf icon SPLT-40M Instructions (ger) (356.09 KB)
application/pdf icon SPLT-40M Instructions (ita) (344.49 KB)
application/pdf icon SPLT-40M Instructions (jpn) (374.7 KB)
application/pdf icon SPLT-40M Instructions (kor) (351.82 KB)
application/pdf icon SPLT-40M Instructions (por) (347.25 KB)
application/pdf icon SPLT-40M Instructions (rus) (309.91 KB)
application/pdf icon SPLT-40M Instructions (spa) (348.93 KB)
application/pdf icon TST-40M-HC40, TST-100M Test Station Instructions (3.07 MB)
application/pdf icon TST-40M-HC40, TST-100M Test Station Instructions (chi) (1.86 MB)
application/pdf icon TST-40M-HC40, TST-100M Test Station Instructions (fre) (3.07 MB)
application/pdf icon TST-40M-HC40, TST-100M Test Station Instructions (ger) (3.07 MB)
application/pdf icon TST-40M-HC40, TST-100M Test Station Instructions (ita) (3.07 MB)
application/pdf icon TST-40M-HC40, TST-100M Test Station Instructions (jpn) (1.88 MB)
application/pdf icon TST-40M-HC40, TST-100M Test Station Instructions (kor) (3.21 MB)
application/pdf icon TST-40M-HC40, TST-100M Test Station Instructions (por) (3.07 MB)
application/pdf icon TST-40M-HC40, TST-100M Test Station Instructions (rus) (3 MB)
application/pdf icon TST-40M-HC40, TST-100M Test Station Instructions (spa) (3.07 MB)
Application Notes
application/pdf icon Guide to determining pressure measurement uncertainty for PM200, PM500 and PM600 Pressure Measurement Modules (479.33 KB)
application/pdf icon High-pressure calibration and characterization in a production process (274.72 KB)
application/pdf icon Performing high-pressure calibration (924.63 KB)
Data Sheets
application/pdf icon 8270A and 8370A Modular Pressure Controllers/Calibrators Data Sheet (1.69 MB)
Firmware
8270A/8370A Embedded Software
Video
How to Calibrate a Pressure Gauge with the Fluke 8270A High-Pressure Controller Calibrator
8270A High-Pressure Controller Calibrator Demo
Introducing the 8270A / 8370A High-Pressure Controller Calibrator
  • Printer-friendly version »
  • Home
  • Products
    • New Products
    • Electrical Calibration
      • Electrical Standards
      • Electrical Calibrators
      • Bench Multimeters
      • Electrical Calibration Software
    • RF Calibration
      • RF Reference Sources
      • RF Calibration Accessories
      • RF Calibration Software
    • Data Acquisition and Test Equipment
      • Bench Multimeters
      • Data Acquisition
      • Data Acquisition Software
    • Temperature Calibration
      • ITS-90 Temperature Standards
        • ITS-90 Fixed-point cells
        • Standard Platinum Resistance Thermometers
        • Maintenance Apparatus
        • Liquid Nitrogen Comparison Calibrator
        • Resistance Bridges
        • Standard Resistors
      • Calibration Baths
        • Compact Calibration Baths
        • Standard Calibration Baths
        • Special Application Baths
        • Bath Accessories
        • Bath Controllers
        • Bath Fluids
      • Industrial Calibrators
        • Field Metrology Wells
        • Metrology Wells
        • Handheld Calibrators
        • Field Dry-Block Calibrators
        • Micro Baths
        • Infrared Calibrators
        • Thermocouple Furnaces
        • Dual Block Dry-Well
        • Zero-point Dry-Well
      • Probes / Sensors
        • Platinum Resistance Thermometers (PRTs)
        • Thermistors
        • Thermocouples
      • Digital Thermometer Readouts
      • Multifunction Calibrators
      • Temperature Calibration Software
    • Humidity Calibration
      • Humidity Generators
      • Humidity Data Loggers and Monitors
    • Pressure Calibration
      • Piston Gauges
        • NMI Piston Gauges
        • Absolute Piston Gauges
        • High Pressure Pneumatic Piston Gauges
        • Hydraulic Piston Gauges
        • Piston Gauge Accessories
      • Automated Pressure Controller / Calibrators
        • Low Pressure Controllers / Calibrators
        • Pneumatic Pressure Controllers / Calibrators
        • High Pressure Pneumatic Controller / Calibrators
        • Hydraulic Controller / Calibrators
      • Pressure Monitors
        • Low Pressure Monitors
        • Digital Pressure Gauges
        • Reference Pressure Monitors
      • Deadweight Testers
        • Pneumatic Deadweight Testers
        • Oil Deadweight Testers
        • Water Deadweight Testers
        • High-Pressure Hydraulic Deadweight Testers
        • Deadweight Tester Accessories
      • Manual Pressure Calibration
        • Pressure Calibrators
        • Pneumatic Pressure Control
        • Hydraulic Pressure Comparators / Pumps
      • Handheld Pressure Calibrators
      • Air Data Calibration
      • Environmental Monitors
      • Pressure Calibration Accessories
      • Pressure Calibration Custom Systems
      • Pressure Calibration Software
    • Flow Calibration
      • Gas Flow Standards
      • Gas Flow Accessories
      • GFS Primary Gravimetric Flow Standard
      • Flow Calibration Software
    • Process Calibration Tools
      • Temperature Calibrators
        • Handheld Temperature Calibrators
        • Dry-Block Calibrators and Micro-Baths
        • Precision Digital Thermometers
        • Temperature Probes
        • Infrared Calibrators
        • Hygro Thermometer with Data Logging
      • Pressure Calibrators
        • Digital Pressure Calibrators
        • Handheld Pressure Calibrators
        • Deadweight Testers
        • Precision Digital Pressure Gauges
        • Calibration Hand Pumps
      • Multifunction Calibrators
      • mA Loop Calibrators
      • Process Calibration Software
    • Calibration Software
      • MET/CAL® Software
      • MET/CAL® Support
      • Asset Management Software
      • Temperature Calibration Software
      • Pressure Calibration Software
      • Flow Calibration Software
      • Mechanical / Dimensional Calibration Software
    • Service and Support
    • All Calibration Instruments
    • Handheld Test Tools
  • Purchase Info
    • Where to Buy
    • Request a Quote
    • Request a Demo
    • Request a Sales Consultation
    • Certified Pre-Owned Equipment
    • General Services Administration (GSA)
    • Financing Program
    • National Stock Numbers (NSNs)
    • Payment Options and Tax Info
  • News
    • Press Releases
    • Promotions
    • Industry Links
    • Metrology Salary Survey
  • Training and Events
    • Conferences and Exhibitions
    • Training Courses
    • User Group Meetings
    • Web Seminars
      • Live Seminars
      • On-Demand Seminars
  • Literature and Education
    • Education Hub
    • About Calibration
    • Articles and Education
    • Product Literature
    • Product Manuals (User Guides)
    • Videos and Virtual Demos
    • Resource Centers
    • Blog
  • Service and Support
    • Service Request (RMA)
    • Service Plans
    • Technical Support
    • Knowledge Base
    • Accreditations
    • Authorized Service Centers
    • Calibration Certificates
    • Community Forum
    • My MET/SUPPORT
      • Activate
      • Procedures
      • Software
      • Technical Bulletins
      • Priority Support
      • Manuals
    • Product Manuals (User Guides)
    • Safety Data Sheets (SDS)
    • Recycle Program
    • Safety, Service, and Product Notices
    • Software Downloads
    • Warranties
    • Tools
      • PT100 Calculator
      • ITS-90 Reference Function Calculator
      • Thermocouple Table Voltage Calculator
      • Thermocouple Voltage to Temperature Calculator
  • About Us
    • Contact Us
    • Visit Us
    • Employment
    • Fluke Calibration
      • Hart Scientific Temperature Calibration
      • DH Instruments Pressure and Flow Calibration
      • Pressurements Pressure Calibration
      • Ruska Pressure Calibration
    • Fluke Companies
    • Integrity and Compliance
    • Frequently Asked Questions
    • Why buy Fluke Calibration ?
Home|Products|Pressure Calibration|Automated Pressure Controller / Calibrators|High Pressure Pneumatic Controller / Calibrators|8270A and 8370A Modular High-Pressure Controllers / Calibrators

Sidebar Request a Quote

Request a quote

Your information is protected by our privacy policy.

©1995-2023 Fluke Corporation
             

Secondary menu

  • Disclaimer
  • Privacy Statement
  • Terms of Use
  • Terms of Sale