The economical way to calibrate meters, clamps and more
If you need to calibrate digital multimeters and clamp meters to comply with ISO 9000 or other quality standards, the Fluke 5500E offers an accurate and economical solution. It calibrates a wide variety of digital multimeters, clamp meters, and more with a single, easy-to-use instrument.
Choose the Fluke 5500E for easy, economical calibration of:
- Handheld digital multimeters
- Bench multimeters (up to 4½ digits)
- Clamp meters
- Panel meters
- Electronic thermometers
- Chart recorders
- Oscilloscope recorders
- XY recorders
- Data loggers
All the functions you need
The 5500E has a wide range of outputs available from a single calibration source. These include dc and ac voltages up to 1020 V, dc and ac currents up to 550 A (using the 5500A/COIL, 50 turn current coil accessory) and variable resistances up to 330 MΩ. The 5500E also provides continuously variable capacitance values up to 1.1 mF. For temperature calibration applications, thermocouples and RTDs are simulated and thermocouple signals can be measured. It also generates digitally synthesized extended bandwidth sine, truncated sine, triangle and square waveforms. The 5500E gives you broad workload coverage in one economically priced package.
Easy-to-use operation
While the Fluke 5500E calibrator helps you do more work, it also makes it easier to get work done. Its intuitive design makes operating it as natural as turning on a light switch, reducing references to the manual. For most tasks, your hand moves from the left to right, keeping you from having to make long, illogical or uncomfortable movements. Most functions require minimal keystrokes. The 5500E is also easy on your budget because no additional fixtures are needed and you can use it with conventional test leads.
Automate calibration for documented, consistent efficiency
With quality management standards like ISO 9000, there is a lot more to calibration than just making measurements. You also have documentation, control and reporting requirements to meet. Optional Microsoft Windows®-based Fluke metrology software simplifies the documentation of your procedures, adequacy and traceability. It also collects and reports calibration results information and helps you to consistently, quickly and efficiently calibrate a wide variety of instruments. With it your entire calibration process—from creating and executing procedures through results data collection and reporting—can be automated. Automated metrology is done by using a suite of applications called MET/CAL® Plus Calibration Management Software. Used with the MET/BASE-7 metrology database, the 5500/CAL-L license provides RS-232 instrument control and operates with the Fluke 5500A, 5520A, and 5800A calibrators in addition to the 5500E. If you need IEEE instrument control or want to automate the calibration of additional instruments, you can step up to GIPB based instrument control with the MET/CAL-L license.
Technical Specifications |
|
Voltage DC | Range: 0 to ±1020V Best 1 Year Specification: ±50 ppm of setting |
Current DC | Range: 0 to ±11A Best 1 Year Specification: ±0.01% of setting |
Resistance | Range: 0 to 3.29.999 MΩ Best 1 Year Specification: ±0.009% of setting |
Voltage AC | Range: 1 mV to 1020V 10 Hz to 500 kHz, Sine Best 1 Year Specification: ±0.03% of setting |
Current AC | Range: 29 mA to 11A 10 Hz to 10 kHz, Sine Best 1 Year Specification: ±0.06% of setting |
Capacitance | Range: 0.33 nF to 1.1 mF Best 1 Year Specification: ±0.25% of setting |
Thermocouple Source and Measure | Range: -250°C to +2316°C (11 types) Best 1 Year Specification: ± 0.14°C of setting |
RTD Source | Range: -200°C to +630°C (8 types) Best 1 Year Specification: ±0.03°C of setting |
Frequency | Range: 0.01 Hz to 2.0 MHz Best 1 Year Specification: ±25 ppm of setting |
General Specifications |
|
Warm up Time | Twice the time since last warmed up, to a maximum of 30 minutes |
Settling Time | Less than 5 seconds for all functions and ranges except as noted |
Standard Interfaces | IEEE-488 (GPIB), RS-232, 5725A (5500E only) |
Temperature Performance | Operating: 0°C to 50°C Calibration: (tcal): 15°C to 35°C Storage: -20°C to 70°C |
Temperature Coefficient | Temperature coefficient for temperatures outside tcal ± 5°C is 10% of the 90-day specification (or 1-year, as applicable) per °C |
Relative Humidity | Operating: < 80% to 30°C, < 70% to 40°C, < 40% to 50°C Storage: < 95%, non-condensing |
Altitude | Operating: 3,050m (10,000 ft) maximum Non-operating: 12,200m (40,000 ft) maximum |
Safety | Designed to comply with IEC 1010-1 (1992-1); ANSI/ISA-S82.01-1994; CAN/CSA-C22.2 No. 1010.1-92 |
Analog Low Isolation | 20V |
EMC | Designed to comply with FCC Rules Part 15 |
Line Power | Line Voltage (selectable): 100V, 120V, 220V, 240V Line Frequency: 47 to 63 Hz Line Voltage Variation: : ± 10% about line voltage setting |
Power Consumption | 300 VA |
Dimensions | Height: 17.8 cm (7 in), standard rack increment, plus 1.5 cm (0.6 in) for feet on bottom of unit Width: 43.2 cm (17 in), standard rack width Depth: 47.3 cm (18.6 in) overall |
Weight (without options) | 20 kg (44 lbs.) |
Absolute Uncertainty Definition | 5500E, 5500A and 5520A uncertainty specifications include stability, temperature coefficient, linearity, line and load regulation, and the traceability of the external standards used for calibration. You do not need to add anything to determine the total uncertainty of your calibrator for the temperature range indicated. |
Specification Confidence Interval | > 99% |
- Startseite
- Produkte
- Neue Produkte
- Elektrische Kalibrierung
- HF-Kalibrierung
- Datenerfassung und Testgeräte
- Temperaturkalibrierung
- Feuchtekalibrierung
- Druckkalibrierung
- Kolbenmessgeräte
- Controller/Kalibratoren
- Druckmonitore
- Druckwaagen
- Manuelle Kalibratoren und Monitore
- Handheld Pressure Calibrators
- Luftdaten-Kalibrierung
- Messgeräte zur Überwachung der Umgebungsbedingungen
- Druckkalibrierungszubehör
- Benutzerdefinierte Druckkalibriersysteme
- Software zur Druckkalibrierung
- Durchflusskalibrierung
- Prozesskalibratoren
- Kalibriersoftware
- Service und Support
- Alle Kalibriergeräte
- Hand-Messgeräte
- Kaufinfo
- Aktuelles
- Schulung/Veranstaltungen
- Literatur/Ausbildung
- Service/Unterstützung
- Service Request (RMA)
- Serviceprogramme
- Technischer Support
- Wissensbasis
- Akkreditierung
- Autorisierte Servicezentren
- Calibration Certificates
- Community Forum
- My MET/SUPPORT
- Produkthandbücher (Bedienungsanleitungen)
- Sicherheitsdatenblätter (SDS)
- Recyclingprogramm
- Safety, Service, and Product Notices
- Gewährleistungen
- Software-Downloads
- Über uns
Sidebar Request a Quote
Angebot anfordern